Your browser doesn't support javascript.
loading
Highly Sensitive Fluorescent pH Microsensors Based on the Ratiometric Dye Pyranine Immobilized on Silica Microparticles.
Chandra, Anil; Prasad, Saumya; Iuele, Helena; Colella, Francesco; Rizzo, Riccardo; D'Amone, Eliana; Gigli, Giuseppe; Del Mercato, Loretta L.
Afiliação
  • Chandra A; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Prasad S; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Iuele H; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Colella F; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Rizzo R; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • D'Amone E; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Gigli G; Institute of Nanotechnology of National Research Council (CNR-NANOTEC) c/o Campus Ecotekne, via Monteroni, 73100, Lecce, Italy.
  • Del Mercato LL; Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, via Arnesano, Lecce, 73100, Italy.
Chemistry ; 27(53): 13318-13324, 2021 Sep 20.
Article em En | MEDLINE | ID: mdl-34231936
ABSTRACT
Pyranine (HPTS) is a remarkably interesting pH-sensitive dye that has been used for plenty of applications. Its high quantum yield and extremely sensitive ratiometric fluorescence against pH change makes it a very favorable for pH-sensing applications and the development of pH nano-/microsensors. However, its strong negative charge and lack of easily modifiable functional groups makes it difficult to use with charged substrates such as silica. This study reports a methodology for noncovalent HPTS immobilization on silica microparticles that considers the retention of pH sensitivity as well as the long-term stability of the pH microsensors. The study emphasizes the importance of surface charge for governing the sensitivity of the immobilized HPTS dye molecules on silica microparticles. The importance of the immobilization methodology, which preserves the sensitivity and stability of the microsensors, is also assessed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Silício / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Silício / Corantes Fluorescentes Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article