Your browser doesn't support javascript.
loading
High-power near-concentric Fabry-Perot cavity for phase contrast electron microscopy.
Turnbaugh, Carter; Axelrod, Jeremy J; Campbell, Sara L; Dioquino, Jeske Y; Petrov, Petar N; Remis, Jonathan; Schwartz, Osip; Yu, Zanlin; Cheng, Yifan; Glaeser, Robert M; Mueller, Holger.
Afiliação
  • Turnbaugh C; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
  • Axelrod JJ; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
  • Campbell SL; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
  • Dioquino JY; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
  • Petrov PN; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
  • Remis J; California Institute for Quantitative Biosciences (QB3), University of California, Berkeley, California 94720, USA.
  • Schwartz O; Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 7610001, Israel.
  • Yu Z; Department of Biochemistry and Biophysics, University of California San Francisco, San Francisco, California 94158, USA.
  • Cheng Y; Department of Biochemistry and Biophysics, University of California San Francisco, San Francisco, California 94158, USA.
  • Glaeser RM; Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California 94720, USA.
  • Mueller H; Department of Physics, 366 Physics MS 7300, University of California-Berkeley, Berkeley, California 94720, USA.
Rev Sci Instrum ; 92(5): 053005, 2021 May 01.
Article em En | MEDLINE | ID: mdl-34243315
ABSTRACT
Transmission electron microscopy (TEM) of vitrified biological macromolecules (cryo-EM) is limited by the weak phase contrast signal that is available from such samples. Using a phase plate would thus substantially improve the signal-to-noise ratio. We have previously demonstrated the use of a high-power Fabry-Perot cavity as a phase plate for TEM. We now report improvements to our laser cavity that allow us to achieve record continuous wave intensities of over 450 GW/cm2, sufficient to produce the optimal 90° phase shift for 300 keV electrons. In addition, we have performed the first cryo-EM reconstruction using a laser phase plate, demonstrating that the stability of this laser phase plate is sufficient for use during standard cryo-EM data collection.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article