Your browser doesn't support javascript.
loading
Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers.
Hell, N; Beiersdorfer, P; Brown, G V; Lockard, T E; Magee, E W; Shepherd, R; Hoarty, D J; Brown, C R D; Hill, M P; Hobbs, L M R; James, S F; Lynch, C; Caughey, T A.
Afiliação
  • Hell N; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Beiersdorfer P; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Brown GV; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Lockard TE; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Magee EW; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Shepherd R; Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Hoarty DJ; Directorate of Research and Applied Science, AWE Plc, Reading RG7 4PR, United Kingdom.
  • Brown CRD; Directorate of Research and Applied Science, AWE Plc, Reading RG7 4PR, United Kingdom.
  • Hill MP; Directorate of Research and Applied Science, AWE Plc, Reading RG7 4PR, United Kingdom.
  • Hobbs LMR; Directorate of Research and Applied Science, AWE Plc, Reading RG7 4PR, United Kingdom.
  • James SF; Directorate of Research and Applied Science, AWE Plc, Reading RG7 4PR, United Kingdom.
  • Lynch C; Inrad Optics, Northvale, New Jersey 07647, USA.
  • Caughey TA; Inrad Optics, Northvale, New Jersey 07647, USA.
Rev Sci Instrum ; 92(4): 043507, 2021 Apr 01.
Article em En | MEDLINE | ID: mdl-34243402
ABSTRACT
During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. We present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-ß and Ne Lyß lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article