Your browser doesn't support javascript.
loading
Perioperative Anomalous Pulmonary Venous Return Evaluation With Low-Dose Cardiac Computed Tomography.
Xiong, Li; Patel, Mehul D; Biliciler-Denktas, Gurur; Dodge-Khatami, Ali; Salazar, Jorge; Adebo, Dilachew A.
Afiliação
  • Xiong L; Division of Pediatric Cardiology, Department of Pediatrics, 12339University of Texas Health Science Center at Houston, TX, USA.
  • Patel MD; Division of Pediatric Cardiology, Department of Pediatrics, 12339University of Texas Health Science Center at Houston, TX, USA.
  • Biliciler-Denktas G; Division of Pediatric Cardiology, Department of Pediatrics, 12339University of Texas Health Science Center at Houston, TX, USA.
  • Dodge-Khatami A; Division of Pediatric and Congenital Heart Surgery, 25050Steven and Alexandra Cohen Children's Medical Center, New Hyde Park, NY, USA.
  • Salazar J; Division of Pediatric and Congenital Heart Surgery, Department of Pediatric Surgery, 12340University of Texas Health Science Center at Houston, Houston, TX, USA.
  • Adebo DA; Division of Pediatric Cardiology, Department of Pediatrics, 12339University of Texas Health Science Center at Houston, TX, USA.
World J Pediatr Congenit Heart Surg ; 12(4): 529-534, 2021 Jul.
Article em En | MEDLINE | ID: mdl-34278867
ABSTRACT

BACKGROUND:

Low-dose multidetector computed tomographic angiography (MDCTA) is playing an increasingly larger role in the diagnosis of anomalous pulmonary venous return (APVR). Despite advances in new computed tomographic (CT) techniques with radiation dose reduction, there are limited studies describing radiation dose parameters to allow routine use of cardiac CT in infants and children with APVR. This study compares cardiac CT findings with intraoperative findings and describes comprehensive radiation exposure parameters.

METHODS:

A retrospective analysis of 27 patients compared MDCTA and intraoperative or cardiac catheterization findings of the pulmonary venous anatomy.

RESULTS:

A total of 32 MDCTA studies were performed on these 27 patients. Of the 28 studies with subsequent intervention, MDCTA accurately diagnosed the anomalous pulmonary venous anatomy in 27 (96.4%) patients. Narrowing of the pulmonary venous confluence entrance to the coronary sinus was missed on cardiac CT in one patient due to motion artifact, but it was noted intraoperatively. Median estimated effective radiation dose was 0.98 mSv (range 0.39-3.2 mSv), and mean estimated effective radiation dose was 1.1 ± 0.68 mSv. Median total dose length product (DLP) was 25 mGy cm (range 10-83 mGy cm), and mean total DLP was 28 ± 18 mGy cm. Median CTDI volume was 3.8 mGy (range 2.5-14.6 mGy), and mean CTDI volume was 5.0 ± 3.2 mGy.

CONCLUSIONS:

We conclude that modern cardiac MDCTA is the best imaging modality to guide management in both preintervention and postintervention APVR patients. In this study, we describe comprehensive radiation exposure parameters in infants and children with APVR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Síndrome de Cimitarra Tipo de estudo: Observational_studies Limite: Child / Humans / Infant Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Síndrome de Cimitarra Tipo de estudo: Observational_studies Limite: Child / Humans / Infant Idioma: En Ano de publicação: 2021 Tipo de documento: Article