Your browser doesn't support javascript.
loading
Measurement of Endotracheal Tube Positioning on Chest X-Ray Using Object Detection.
Harris, Robert J; Baginski, Scott G; Bronstein, Yulia; Kim, Shwan; Lohr, Jerry; Towey, Steve; Velichkovich, Zeljko; Kabachenko, Tim; Driscoll, Ian; Baker, Brian.
Afiliação
  • Harris RJ; Virtual Radiologic, Eden Prairie, MN, USA. robert.harris@vrad.com.
  • Baginski SG; Virtual Radiologic, Eden Prairie, MN, USA.
  • Bronstein Y; Virtual Radiologic, Eden Prairie, MN, USA.
  • Kim S; Virtual Radiologic, Eden Prairie, MN, USA.
  • Lohr J; Virtual Radiologic, Eden Prairie, MN, USA.
  • Towey S; Virtual Radiologic, Eden Prairie, MN, USA.
  • Velichkovich Z; Virtual Radiologic, Eden Prairie, MN, USA.
  • Kabachenko T; Virtual Radiologic, Eden Prairie, MN, USA.
  • Driscoll I; Virtual Radiologic, Eden Prairie, MN, USA.
  • Baker B; Virtual Radiologic, Eden Prairie, MN, USA.
J Digit Imaging ; 34(4): 846-852, 2021 08.
Article em En | MEDLINE | ID: mdl-34322753
ABSTRACT
Patients who are intubated with endotracheal tubes often receive chest x-ray (CXR) imaging to determine whether the tube is correctly positioned. When these CXRs are interpreted by a radiologist, they evaluate whether the tube needs to be repositioned and typically provide a measurement in centimeters between the endotracheal tube tip and carina. In this project, a large dataset of endotracheal tube and carina bounding boxes was annotated on CXRs, and a machine-learning model was trained to generate these boxes on new CXRs and to calculate a distance measurement between the tube and carina. This model was applied to a gold standard annotated dataset, as well as to all prospective data passing through our radiology system for two weeks. Inter-radiologist variability was also measured on a test dataset. The distance measurements for both the gold standard dataset (mean error = 0.70 cm) and prospective dataset (mean error = 0.68 cm) were noninferior to inter-radiologist variability (mean error = 0.70 cm) within an equivalence bound of 0.1 cm. This suggests that this model performs at an accuracy similar to human measurements, and these distance calculations can be used for clinical report auto-population and/or worklist prioritization of severely malpositioned tubes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traqueia / Intubação Intratraqueal Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traqueia / Intubação Intratraqueal Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article