Your browser doesn't support javascript.
loading
Lung nodule detection in chest X-rays using synthetic ground-truth data comparing CNN-based diagnosis to human performance.
Schultheiss, Manuel; Schmette, Philipp; Bodden, Jannis; Aichele, Juliane; Müller-Leisse, Christina; Gassert, Felix G; Gassert, Florian T; Gawlitza, Joshua F; Hofmann, Felix C; Sasse, Daniel; von Schacky, Claudio E; Ziegelmayer, Sebastian; De Marco, Fabio; Renger, Bernhard; Makowski, Marcus R; Pfeiffer, Franz; Pfeiffer, Daniela.
Afiliação
  • Schultheiss M; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany. manuel.schultheiss@tum.de.
  • Schmette P; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany. manuel.schultheiss@tum.de.
  • Bodden J; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.
  • Aichele J; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Müller-Leisse C; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Gassert FG; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Gassert FT; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Gawlitza JF; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Hofmann FC; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Sasse D; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • von Schacky CE; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Ziegelmayer S; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • De Marco F; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Renger B; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.
  • Makowski MR; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Pfeiffer F; Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Pfeiffer D; Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.
Sci Rep ; 11(1): 15857, 2021 08 04.
Article em En | MEDLINE | ID: mdl-34349135
ABSTRACT
We present a method to generate synthetic thorax radiographs with realistic nodules from CT scans, and a perfect ground truth knowledge. We evaluated the detection performance of nine radiologists and two convolutional neural networks in a reader study. Nodules were artificially inserted into the lung of a CT volume and synthetic radiographs were obtained by forward-projecting the volume. Hence, our framework allowed for a detailed evaluation of CAD systems' and radiologists' performance due to the availability of accurate ground-truth labels for nodules from synthetic data. Radiographs for network training (U-Net and RetinaNet) were generated from 855 CT scans of a public dataset. For the reader study, 201 radiographs were generated from 21 nodule-free CT scans with altering nodule positions, sizes and nodule counts of inserted nodules. Average true positive detections by nine radiologists were 248.8 nodules, 51.7 false positive predicted nodules and 121.2 false negative predicted nodules. The best performing CAD system achieved 268 true positives, 66 false positives and 102 false negatives. Corresponding weighted alternative free response operating characteristic figure-of-merits (wAFROC FOM) for the radiologists range from 0.54 to 0.87 compared to a value of 0.81 (CI 0.75-0.87) for the best performing CNN. The CNN did not perform significantly better against the combined average of the 9 readers (p = 0.49). Paramediastinal nodules accounted for most false positive and false negative detections by readers, which can be explained by the presence of more tissue in this area.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Interpretação de Imagem Radiográfica Assistida por Computador / Redes Neurais de Computação / Nódulo Pulmonar Solitário / Nódulos Pulmonares Múltiplos / Radiologistas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Torácica / Interpretação de Imagem Radiográfica Assistida por Computador / Redes Neurais de Computação / Nódulo Pulmonar Solitário / Nódulos Pulmonares Múltiplos / Radiologistas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article