Your browser doesn't support javascript.
loading
Infection prevention in endoscopy practice: comparative evaluation of re-usable vs single-use endoscopic valves.
Pasquale, L; Maurano, A; Cengia, G; Da Massa Carrara, P; Germanà, B; Graziani, M G; Manes, G; Pisani, A; Golia, M; Marciano, E; Rodella, L; Schiffino, L; Gandolfo, C; Terrosi, C; Cusi, M G.
Afiliação
  • Pasquale L; Gastroenterology and General Medicine Unit, Civil Hospital 'Frangipane' di Ariano Irpino, Avellino, Italy.
  • Maurano A; University Hospital, Mercato S. Severino, Salerno, Italy.
  • Cengia G; Digestive Endoscopy Unit, ASST Garda, Manerbio Hospital, Manerbio, Italy.
  • Da Massa Carrara P; Gastroenterology and Digestive Endoscopy, Azienda USL Toscana Centro, Pistoia, Italy.
  • Germanà B; AULSS1 Dolomiti, Belluno Hospital, Belluno, Italy.
  • Graziani MG; Gastroenterology and Digestive Endoscopy, S. Giovanni Addolorata Hospital, Rome, Italy.
  • Manes G; Gastroenterology and Digestive Endoscopy, ASST Rhodense, Garbagnate Milanese and Rho Hospital, Garbagnate Milanese, Milan, Italy.
  • Pisani A; IRCCS de Bellis, Castellana Grotte, Bari, Italy.
  • Golia M; Diagnostic and Endoscopic Surgery Unit, Monza Hospital, Monza, Italy.
  • Marciano E; Pisana University Hospital, Presidio Cisanello, Pisa, Italy.
  • Rodella L; Surgical Unit, Borgo Trento Hospital, Piazzale Stefani, Verona, Italy.
  • Schiffino L; Digestive Endoscopy Unit, G.B. Grassi Hospital, Ostia, Rome, Italy.
  • Gandolfo C; Santa Maria alle Scotte University Hospital, Siena, Italy.
  • Terrosi C; Virology Unit, Department of Medical Biotechnologies, University of Siena, Siena, Italy.
  • Cusi MG; Santa Maria alle Scotte University Hospital, Siena, Italy.
Infect Prev Pract ; 3(2): 100123, 2021 Jun.
Article em En | MEDLINE | ID: mdl-34368741
ABSTRACT
Re-usable air/water and suction valves used in endoscopes often demonstrate risk of infection. To the authors' knowledge, the safety and efficacy of re-usable and single-use valves have not been compared to date. As such, a laboratory investigation was undertaken to compare the safety and efficacy of re-usable and single-use valves at 11 Italian endoscopy sites. Safety was evaluated by analysing the rinse liquid of reprocessed re-usable valves ready for use, and efficacy was assessed based on the completion of endoscopic procedures without valve malfunction. This study found significantly lower contamination of single-use valves compared with re-usable valves (0 vs 29.1%, respectively; P=0.007) and similar efficacy (97.6 vs 98.8%, respectively; P=ns). Microbiological analysis of the rinse liquid of reprocessed re-usable valves identified various surviving micro-organisms and highlighted their potential pathogenicity. Such data suggest that sterile single-use valves may be safer than re-usable valves, and have comparable performance.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article