Electron Microprobe/SIMS Determinations of Al in Olivine: Applications to Solar Wind, Pallasites and Trace Element Measurements.
Paque, J M; Hofmann, A E; Burnett, D S; Guan, Y; Jurewicz, A J G; Woolum, D S; Ma, C; Rossman, G R.
Afiliação
  • Paque JM; California Institute of Technology, Div. of Geol. and Planet. Sciences, Pasadena, CA 91104.
  • Hofmann AE; California Institute of Technology, Div. of Geol. and Planet. Sciences, Pasadena, CA 91104.
  • Burnett DS; Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91107.
  • Guan Y; California Institute of Technology, Div. of Geol. and Planet. Sciences, Pasadena, CA 91104.
  • Jurewicz AJG; California Institute of Technology, Div. of Geol. and Planet. Sciences, Pasadena, CA 91104.
  • Woolum DS; SESE, Arizona State University, Tempe, AZ, 85287.
  • Ma C; Dept. of Physics, Cal State Fullerton, Fullerton CA 92834.
  • Rossman GR; California Institute of Technology, Div. of Geol. and Planet. Sciences, Pasadena, CA 91104.
Geostand Geoanal Res ; 44(3): 473-484, 2020 Sep.
Article em En | MEDLINE | ID: mdl-34381324
ABSTRACT
Electron probe microanalyzer measurements of trace elements with high accuracy are challenging. Accurate Al measurements in olivine are required to calibrate SIMS implant reference materials for measurement of Al in the solar wind. We adopt a combined EPMA/SIMS approach that is useful for producing SIMS reference materials as well as for EPMA at the ~100 µg g-1 level. Even for mounts not polished with alumina photoelectron spectroscopy shows high levels of Al surface contamination. In order to minimize electron beam current density, a rastered 50 × 100 µm electron beam was adequate and minimized sensitivity to small Al-rich contaminants. Reproducible analyses of eleven SIMS-cleaned spots on San Carlos olivine agreed at 69.3 ± 1.0 µg g-1• The known Al mass fraction was used to calibrate an Al implant into San Carlos. Accurate measurements of Al were made for olivines in the pallasites lmilac, Eagle Station and Springwater. Our focus was on Al in olivine, but our technique could be refined to give accurate electron probe measurements for other contamination-sensitive trace elements. For solar wind, it is projected that the Al/Mg abundance ratio can be determined to 6%, a factor of 2 more precise than the solar spectroscopic ratio.