Your browser doesn't support javascript.
loading
Novel monkey-wrench-shaped microstrip patch sensor for food evaluation and analysis.
Kaur, Jaswinder; Khanna, Rajesh.
Afiliação
  • Nitika; Department of Electronics and Communication Engineering, Thapar Institute of Engineering and Technology, Patiala, India.
  • Kaur J; Department of Electronics and Communication Engineering, Thapar Institute of Engineering and Technology, Patiala, India.
  • Khanna R; Department of Electronics and Communication Engineering, Thapar Institute of Engineering and Technology, Patiala, India.
J Sci Food Agric ; 102(4): 1443-1456, 2022 Mar 15.
Article em En | MEDLINE | ID: mdl-34390496
ABSTRACT

BACKGROUND:

Microwave sensor technology is considered to be a non-destructive and hygienic means for food evaluation and analysis. The rapid progress in microwave sensor technologies motivated us to present a novel monkey-wrench-shaped microstrip patch sensor for evaluating food quality. The proposed antenna is considered as a liquid sensor to detect adulteration in liquids by examining the relationship between concentration, shift in resonant frequency, and variation in reflection coefficient.

RESULTS:

The sensor has a compact size of 17 × 14 mm2 imprinted on an FR4 substrate of thickness 1.57 mm. This microwave system is proposed for monitoring overall milk quality using a microstrip sensor and has considerably good numerical sensitivity and accuracy (13.11% and 88.5% respectively), which makes the system attractive for detecting adulteration. Further, the Q-factor for the proposed sensor is 209 and has a standard deviation less than the difference between non-adulterated and adulterated values, giving resolution high enough to distinguish adulteration with an acceptable statistical accuracy. In this study, different milk categories (buffalo, goat, and cow milk) are considered as liquid samples to detect adulteration by demonstrating the variation in reflection coefficient due to change in dielectric properties for the following different cases (i) adulteration of milk with water; (ii) adulteration of milk with synthetic milk powder; (iii) adulteration of milk with caustic soda; and (iv) adulteration of milk with vegetable oil. The referred variation in reflection coefficient and resonant frequency is due to a change in the dielectric properties of a liquid when a varying concentration of an adulterant/solute is added to the liquid sample.

CONCLUSION:

The simulation and measured results show good agreement that validates the proposed sensor for food adulteration detection with high sensitivity. In terms of performance, the proposed sensor shows accuracy with high spatial resolution and reduced penetration depth to detect the adulteration in various milk samples (i.e. buffalo, goat, and cow milk). © 2021 Society of Chemical Industry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Leite Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Leite Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article