Your browser doesn't support javascript.
loading
Recumbent Total Skin Electron Beam Therapy.
Ackerson, Bradley G; Wu, Qiuwen; Craciunescu, Oana; Oyekunle, Taofik; Niedzwiecki, Donna; Gupton, Jennie; Laug, Patrick; Brumfield, Karibee; Crain, Erin; Champ, Colin E; Kelsey, Chris R.
Afiliação
  • Ackerson BG; Departments of Radiation Oncology.
  • Wu Q; Departments of Radiation Oncology.
  • Craciunescu O; Departments of Radiation Oncology.
  • Oyekunle T; Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina.
  • Niedzwiecki D; Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina.
  • Gupton J; Departments of Radiation Oncology.
  • Laug P; Departments of Radiation Oncology.
  • Brumfield K; Departments of Radiation Oncology.
  • Crain E; Departments of Radiation Oncology.
  • Champ CE; Departments of Radiation Oncology.
  • Kelsey CR; Departments of Radiation Oncology.
Adv Radiat Oncol ; 6(4): 100698, 2021.
Article em En | MEDLINE | ID: mdl-34409205
ABSTRACT

PURPOSE:

Our purpose was to describe preliminary dosimetric and clinical results of a recumbent total skin electron beam therapy (TSEBT) technique and compare this to a conventional standing TSEBT technique. METHODS AND MATERIALS A customized treatment platform with recessed side wheels was constructed and commissioned for patients to be treated in a recumbent position. Dosimetric and clinical information was collected for patients treated with this new recumbent technique in addition to that of a cohort of patients treated contemporaneously using the conventional standing method. Dose delivery and clinical outcomes were compared for patients treated with the recumbent and standing techniques.

RESULTS:

Between 2017 and 2019, 27 patients were treated with TSEBT with the recumbent (n = 13) or conventional standing technique (n = 14) at our institution. Measured dose at 15 body sites could be directly compared. Of these, 10 showed no significant difference between the two techniques while five sites showed significant differences in median measured dose, including the top of left shoulder, right biceps, bend of left elbow, upper back, and medial right thigh (P < .003). Measured dose was significantly higher with the standing technique at these sites with the exception of the upper back. Rates of complete response (25% vs 23%), partial response (50% vs 69%), and stable disease (17% vs 8%) were similar between the standing and recumbent cohorts, respectively (P = .78).

CONCLUSIONS:

We have developed, commissioned, and implemented a floor-based, recumbent technique that allows for treatment of patients who would otherwise not be eligible for TSEBT. Dosimetric and clinical measurements suggest that this technique is a viable alternative to the standing method.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article