First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker.
Tanaka, Sodai; Miyamoto, Naoki; Matsuo, Yuto; Yoshimura, Takaaki; Takao, Seishin; Matsuura, Taeko.
Afiliação
  • Tanaka S; Institute for Quantum Medical Science, Quantum Medical Science Directorate, National Institutes for Quantum and Radiological Science and Technology, Chiba, Chiba, 263-8555, Japan.
  • Miyamoto N; Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan.
  • Matsuo Y; Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Hokkaido, 060-8648, Japan.
  • Yoshimura T; Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido 060-0812, Japan.
  • Takao S; Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan.
  • Matsuura T; Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan.
Phys Med Biol ; 66(18)2021 09 09.
Article em En | MEDLINE | ID: mdl-34433146
ABSTRACT
Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography (pRG) were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated pRG images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure.