Your browser doesn't support javascript.
loading
A Laser Reduced Graphene Oxide Grid Electrode for the Voltammetric Determination of Carbaryl.
Saqib, Muhammad; Dorozhko, Elena V; Barek, Jiri; Vyskocil, Vlastimil; Korotkova, Elena I; Shabalina, Anastasiia V.
Afiliação
  • Saqib M; Department of Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk, Russia.
  • Dorozhko EV; UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Albertov 6, CZ-12843 Prague 2, Czech Republic.
  • Barek J; Department of Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk, Russia.
  • Vyskocil V; Department of Chemical Engineering, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk, Russia.
  • Korotkova EI; UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Albertov 6, CZ-12843 Prague 2, Czech Republic.
  • Shabalina AV; UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Albertov 6, CZ-12843 Prague 2, Czech Republic.
Molecules ; 26(16)2021 Aug 20.
Article em En | MEDLINE | ID: mdl-34443639
ABSTRACT
Laser-reduced graphene oxide (LRGO) on a polyethylene terephthalate (PET) substrate was prepared in one step to obtain the LRGO grid electrode for sensitive carbaryl determination. The grid form results in a grid distribution of different electrochemically active zones affecting the electroactive substance diffusion towards the electrode surface and increasing the electrochemical sensitivity for carbaryl determination. Carbaryl is electrochemically irreversibly oxidized at the secondary amine moiety of the molecule with the loss of one proton and one electron in the pH range from 5 to 7 by linear scan voltammetry (LSV) on the LRGO grid electrode with a scan rate of 300 mV/s. Some interference of the juice matrix molecules does not significantly affect the LSV oxidation current of carbaryl on the LRGO grid electrode after adsorptive accumulation without applied potential. The LRGO grid electrode can be used for LSV determination of carbaryl in fruit juices in the concentration range from 0.25 to 128 mg/L with LOD of 0.1 mg/L. The fabrication of the LRGO grid electrode opens up possibilities for further inexpensive monitoring of carbaryl in other fruit juices and fruits.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbaril / Grafite Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbaril / Grafite Idioma: En Ano de publicação: 2021 Tipo de documento: Article