Your browser doesn't support javascript.
loading
Development of a simple and reliable method for α-amanitin detection in rat plasma and its application to a toxicokinetic study.
Mao, Zhengsheng; Yu, Youjia; Sun, Hao; Cao, Yue; Jiang, Qiaoyan; Chu, Chunyan; Sun, Yang; Huang, Shuainan; Zhang, Jinsong; Chen, Feng.
Afiliação
  • Mao Z; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Yu Y; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Sun H; Department of Emergency, Jiangsu Province Hospital, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Cao Y; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Jiang Q; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Chu C; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Sun Y; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Huang S; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
  • Zhang J; Department of Emergency, Jiangsu Province Hospital, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Chen F; Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, China.
Rapid Commun Mass Spectrom ; 35(21): e9184, 2021 Nov 15.
Article em En | MEDLINE | ID: mdl-34472672
ABSTRACT
RATIONALE α-Amanitin is a highly toxic peptide widely found in species of poisonous mushrooms. The matrix effect has been a major obstacle for accurate determination of α-amanitin in plasma samples by liquid chromatography/tandem mass spectrometry (LC/MS/MS). In this study, the strategy to eliminate the matrix effect of α-amanitin with a one-step dilution approach after deproteinization was applied.

METHODS:

Rat plasma samples were processed by protein precipitation with methanol followed by a nine-fold dilution with pure water. The matrix effect value of α-amanitin was 19.7%-22.2% by protein precipitation and then changed to 87.5%-88.7% after dilution. α-Amanitin and the internal standard (roxithromycin) were analyzed on an ACQUITY UPLC® BEH C18 (50 mm × 2.1 mm, 1.7 µm) column within 3.0 min by gradient elution.

RESULTS:

The linear ranges were 0.90-600 ng/mL with a correlation coefficient r >0.9958. A lower limit of quantification (LLOQ) of 0.90 ng/mL was achieved using only 50 µL of rat plasma. The intra- and inter-day precisions for the analyte ranged from 3.2% to 7.5% and 3.1% to 7.1%, respectively, and the accuracy ranged from -5.3% to -8.0%.

CONCLUSIONS:

The matrix effect of α-amanitin was reduced by sample dilution after plasma deproteinization. A reliable LC/MS/MS method for the determination of α-amanitin in rat plasma was developed. This method was successfully applied for a toxicokinetic study of rats after intravenous injection of α-amanitin with a subacute toxicity dose at 0.10 mg/kg.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Espectrometria de Massas em Tandem / Alfa-Amanitina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Espectrometria de Massas em Tandem / Alfa-Amanitina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article