Molecularly imprinted photoelectrochemical sensor for detecting tetrabromobisphenol A in indoor dust and water.
Li, Zhi; Hu, Jiayue; Lou, Zaizhu; Zeng, Lixi; Zhu, Mingshan.
Afiliação
  • Li Z; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, People's Republic of China.
  • Hu J; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, People's Republic of China.
  • Lou Z; Institute of Nanophotonics, Jinan University, Guangzhou, 511443, People's Republic of China.
  • Zeng L; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, People's Republic of China.
  • Zhu M; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, People's Republic of China. zhumingshan@jnu.edu.cn.
Mikrochim Acta ; 188(10): 320, 2021 Sep 03.
Article em En | MEDLINE | ID: mdl-34480212
The gradual emissions of tetrabromobisphenol A (TBBPA) from the primitive recycling of E-waste create human health threats, which urgently require to develop an efficient, rapid yet simple detection method. The present study conducts a highly sensitive molecularly imprinted photoelectrochemical sensor (MIPES) containing molecularly imprinted (MI)-TiO2, Au, and reduced graphene oxide for the trace detection of TBBPA in indoor dust and surface water from an E-waste recycling area. The photocurrent response is used to evaluate the sensing performance of the MIPES toward TBBPA detection. The working potential for amperometry is 0.48 V. The wavelength range for photoelectrochemical detection is 320-780 nm. The sensor shows a detection range of 1.68 to 100 nM with a low limit of detection of 0.51 nM (LOD = 3 sb/S) and a limit of quantification of 1.68 nM (LOQ = 3.3 LOD). In addition, the MIPES sensor exhibits rapid, excellent reproducibility, selectivity, and long-term stability toward TBBPA detection. The relative standard deviation of three measurements for real samples is less than 7.0%, and the recovery range is 90.0-115%. The surface of molecular imprinting contributes to the high charge separation and sensing photocurrent response of TBBPA, which is confirmed by single-particle photoluminescence spectroscopy. The present study provides a new facile sensor with highly sensitive yet rapid response to detect environmental pollutants in E-waste by using the MIPES.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Poluentes Químicos da Água / Bifenil Polibromatos / Técnicas Eletroquímicas Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Poluentes Químicos da Água / Bifenil Polibromatos / Técnicas Eletroquímicas Idioma: En Ano de publicação: 2021 Tipo de documento: Article