Your browser doesn't support javascript.
loading
Solute Diffusion into Polymer Swollen by Supercritical CO2 by High-Pressure Electron Paramagnetic Resonance Spectroscopy and Chromatography.
Gromov, Oleg I; Kostenko, Mikhail O; Petrunin, Alexander V; Popova, Anastasia A; Parenago, Olga O; Minaev, Nikita V; Golubeva, Elena N; Melnikov, Mikhail Ya.
Afiliação
  • Gromov OI; Faculty of Chemistry, Lomonosov Moscow State University, Leninskiye Gory, 1-3, 119991 Moscow, Russia.
  • Kostenko MO; Kurnakov Institute of General and Inorganic Chemistry of the Russian Academy of Sciences, Leninsky Prosp. 31, 119991 Moscow, Russia.
  • Petrunin AV; Institute of Physical Chemistry, RWTH Aachen University, 52056 Aachen, Germany.
  • Popova AA; Faculty of Chemistry, Lomonosov Moscow State University, Leninskiye Gory, 1-3, 119991 Moscow, Russia.
  • Parenago OO; Faculty of Chemistry, Lomonosov Moscow State University, Leninskiye Gory, 1-3, 119991 Moscow, Russia.
  • Minaev NV; Kurnakov Institute of General and Inorganic Chemistry of the Russian Academy of Sciences, Leninsky Prosp. 31, 119991 Moscow, Russia.
  • Golubeva EN; Federal Scientific Research Centre "Crystallography and Photonics" RAS, Institute of Photon Technologies, Pionerskaya Str. 2, Troitsk, 108840 Moscow, Russia.
  • Melnikov MY; Faculty of Chemistry, Lomonosov Moscow State University, Leninskiye Gory, 1-3, 119991 Moscow, Russia.
Polymers (Basel) ; 13(18)2021 Sep 10.
Article em En | MEDLINE | ID: mdl-34577959
ABSTRACT
High-pressure electron paramagnetic resonance (EPR) was used to measure translational diffusion coefficients (Dtr) of a TEMPONE spin probe in poly(D,L-lactide) (PDLLA) and swollen in supercritical CO2. Dtr was measured on two scales macroscopic scale (>1 µm), by measuring spin probe uptake by the sample; and microscopic scale (<10 nm), by using concentration-dependent spectrum broadening. Both methods yield similar translational diffusion coefficients (in the range 5-10 × 10-12 m2/s at 40-60 °C and 8-10 MPa). Swollen PDLLA was found to be homogeneous on the nanometer scale, although the TEMPONE spin probe in the polymer exhibited higher rotational mobility (τcorr = 6 × 10-11 s) than expected, based on its Dtr. To measure distribution coefficients of the solute between the swollen polymer and the supercritical medium, supercritical chromatography with sampling directly from the high-pressure vessel was used. A distinct difference between powder and bulk polymer samples was only observed at the start of the impregnation process.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article