Your browser doesn't support javascript.
loading
Nickel phosphide on Ni foam as anode and peroxymonosulfate as the chemical oxidizer for effective direct urea fuel cell.
Hao, Jingwei; Zhao, Shen; Mao, Ran; Zhao, Xu.
Afiliação
  • Hao J; Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhao S; Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
  • Mao R; Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China. Electronic address: maoran@rcees.ac.cn.
  • Zhao X; Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China.
J Environ Sci (China) ; 110: 84-91, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34593197
ABSTRACT
The direct urea fuel cell (DUFC) is a low cost and competitive approach for contemporaneous urine or urea-contaminated wastewater treatment and electricity generation. However, the lack of efficient urea oxidation reaction (UOR) electrocatalysts and suitable electron acceptors remains a challenge for practical applications. Here, we developed a DUFC system using Ni2P@Ni foam as the anode and peroxymonosulfate (PMS) as the chemical oxidizers. The Ni2P@Ni foam anode showed a high oxidation activity for UOR with an onset potential of 0.30 V vs. Ag/AgCl and Tafel slope of 34.4 mV/dec. PMS with high theoretical potential improved the cell voltage to 1.43 V. A power density of DUFC up to 4.91 mW/cm2 was achieved using PMS at room temperature, which was approximately twice as high as using H2O2 (2.38 mW/cm2). NiII/NiIII was the redox active species on the Ni2P anode in the DUFC process, and NiII was electrochemically oxidized to NiIII, which reverted to NiII by urea reduction. When real human urine was used as the fuel, a power density of 4.46 mW/cm2 can be achieved at room temperature. This DUFC with high cell performance showed potential application in urea wastewater treatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ureia / Níquel Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ureia / Níquel Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article