Your browser doesn't support javascript.
loading
An eco-friendly solvent-free reaction based on peptide probes: design an extraction-free method for analysis of acrylamide under microliter volume.
Li, Yi-Shan; Suen, Jau-Ling; Tseng, Wei-Lung; Lu, Chi-Yu.
Afiliação
  • Li YS; Department of Biochemistry, College of Medicine, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan.
  • Suen JL; Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan.
  • Tseng WL; Department of Chemistry, College of Science, National Sun Yat-Sen University, Kaohsiung, 80424, Taiwan.
  • Lu CY; Department of Biochemistry, College of Medicine, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan. cylu@kmu.edu.tw.
Anal Bioanal Chem ; 413(30): 7531-7539, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34635932
Acrylamide is a group 2A carcinogen and potential endocrine disruptor that can enter the ecosystem by various routes and has recently become a dangerous pollutant. This widely used chemical can enter the human body via air inhalation, food or water consumption, or skin contact. In this study, we developed a peptide probe for the detection of acrylamide by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) after its micro-tagging with a peptide. Direct detection of acrylamide by MALDI-TOF MS is not feasible due to its poor ionization in the MALDI interface, which hinders its analysis by the technique. After microwave irradiation for 2 min, the formed acrylamide-peptide derivative was detected easily by MALDI-TOF MS without the need for extraction procedures. The procedure does not involve organic solvents and a water-soluble peptide that allows detection of acrylamide in small sample volumes with a limit of detection (LOD) of 0.05 ng/µL. The relative standard deviation (RSD) and relative error (RE) of the measurements were < 6.7% for intra- and inter-day assays. Gel-washing solutions from a polyacrylamide gel experiment were used as a model to study the efficiency of the developed method. Finally, we used the proposed method for the detection of free acrylamide in small volumes of lung epithelial cells (a model to test the air inhalation of acrylamide under a tiny volume of sample) and human urine. The developed method will enable rapid acrylamide detection in environmental and biological samples via a green approach based on microwave-assisted derivatization in water alongside the use of a less toxic derivatization reagent, reusable target plate, and miniaturization protocols.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Sondas Moleculares / Acrilamida Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Sondas Moleculares / Acrilamida Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article