Your browser doesn't support javascript.
loading
A Comparative Analysis of the Piezoelectric Ultrasonic Appliance and Trephine Bur for Apical Location: An In Vitro Study.
Cáceres Madroño, Esther; Rodríguez Torres, Paulina; Oussama, Soraya; Zubizarreta-Macho, Álvaro; Bufalá Pérez, María; Mena-Álvarez, Jesús; Riad Deglow, Elena; Hernández Montero, Sofía.
Afiliação
  • Cáceres Madroño E; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Rodríguez Torres P; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Oussama S; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Zubizarreta-Macho Á; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Bufalá Pérez M; Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain.
  • Mena-Álvarez J; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Riad Deglow E; Department of Endodontics, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
  • Hernández Montero S; Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
J Pers Med ; 11(10)2021 Oct 15.
Article em En | MEDLINE | ID: mdl-34683175
ABSTRACT
To compare and contrast the accuracy of piezoelectric ultrasonic insert (PUI) and trephine bur (TB) osteotomy site preparation techniques for apical location. (1) Material and

methods:

A total of 138 osteotomy site preparations were randomly distributed into one of two study groups. Group A TB technique (n = 69) and B PUI technique (n = 69). A preoperative cone-beam computed tomography scan and an intraoral scan were performed and uploaded to implant-planning software to plan the virtual osteotomy site preparations for apical location. Subsequently, the osteotomy site preparations were performed in the experimental models with both osteotomy site preparation techniques and a postoperative CBCT scan was performed and uploaded into the implant-planning software and matched with the virtually planned osteotomy site preparations to measure the deviation angle and horizontal deviation as captured at the coronal entry point and apical end-point between osteotomy site preparations using Student's t-test statistical analysis. (2)

Results:

The paired t-test found statistically significant differences at the coronal entry-point deviations (p = 0.0104) and apical end-point deviations (p = 0.0104) between the TB and PUI study groups; however, no statistically significant differences were found in the angular deviations (p = 0.309) between the trephine bur and piezoelectric ultrasonic insert study groups. (3)

Conclusions:

The results showed that the TB is more accurate than the PUI for apical location.