Your browser doesn't support javascript.
loading
Rational design of allosterically regulated toehold mediated strand displacement circuits for sensitive and on-site detection of small molecule metabolites.
Lin, Haosi; Rodríguez-Serrano, Alan F; Hsing, I-Ming.
Afiliação
  • Lin H; Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. kehsing@ust.hk.
  • Rodríguez-Serrano AF; Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. kehsing@ust.hk.
  • Hsing IM; Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. kehsing@ust.hk.
Analyst ; 146(23): 7144-7151, 2021 Nov 22.
Article em En | MEDLINE | ID: mdl-34734587
Development of small molecule biosensors enables rapid and de-centralized small molecule detection that meets the demands of routine health monitoring and rapid diagnosis. Among them, allosteric transcription factor (aTF)-based biosensors have shown potential in modular design of small molecule detection platforms due to their ligand-regulated DNA binding activity. Here, we expand the capabilities of a biosensor that leverages the aTF-based regulation of toehold-mediated strand displacement (TMSD) circuits for uric acid (UA) detection in non-invasive salivary samples by utilizing the UA-responsive aTF HucR. The impact of the low ligand affinity of the native HucR was addressed by engineering a two-pass TMSD circuit with in silico rational design. This combined strategy achieved enrichment of the output signal and overcame the negative impact of the matrix effect on the sensitivity and overall response of the biosensor when using real samples, which enabled semi-quantitative detection in the normal salivary UA levels. As well, enhancements provided by the two-pass design halved the turnaround time to less than 15 minutes. To sum up, the two-cycle DNA circuit design enabled aTF-based simple, rapid and one-step non-invasive salivary UA detection, showing its potential in metabolite detection for health monitoring.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article