Your browser doesn't support javascript.
loading
Agreement between single plane and biplane derived angiographic fractional flow reserve in patients with intermediate coronary artery stenosis.
Ando, Jiro; Otani, Katharina; Redel, Thomas; Minatsuki, Shun; Kikuchi, Hironobu; Kodera, Satoshi; Komuro, Issei.
Afiliação
  • Ando J; Department of Cardiovascular Medicine, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. jandokkr@gmail.com.
  • Otani K; Advanced Therapies Innovation Department, Siemens Healthcare K.K, Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa-ku, Tokyo, 114-8644, Japan.
  • Redel T; Advanced Therapies Innovation Department, Siemens Healthcare GmbH, Siemensstr. 1, 91301, Forchheim, Germany.
  • Minatsuki S; Department of Cardiovascular Medicine, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
  • Kikuchi H; Department of Cardiovascular Medicine, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
  • Kodera S; Department of Cardiovascular Medicine, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
  • Komuro I; Department of Cardiovascular Medicine, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Heart Vessels ; 37(4): 549-554, 2022 Apr.
Article em En | MEDLINE | ID: mdl-34762151
ABSTRACT
Fractional flow reserve (FFR) is often used to evaluate the physiological severity of intermediate coronary stenoses, but less-invasive assessment methods are desirable. We evaluated the feasibility of angiographic FFR (angioFFR) calculated from two projections acquired simultaneously by a biplane C-arm system and angioFFR calculated from two projections acquired independently by one plane of the same biplane C-arm system. AngioFFR was validated against FFR in terms of detection of hemodynamically relevant coronary artery stenoses. Twenty-two Patients who underwent angiography and FFR for coronary artery disease were included. We used a non-commercial prototype to calculate biplane angioFFR for 22 vessels (19 LAD, 1 LCx, 2 RCA) and single plane angioFFR for 17 of the same 22 vessels. FFR < 0.8 was measured in 8 vessels. The Pearson correlation coefficients with FFR were 0.55 for single plane angioFFR and 0.61 for biplane angioFFR and the diagnostic accuracies were 88% (95% CI 73-100%) for single plane angioFFR and 86% (95% CI 72-100%) for biplane angioFFR. Bland-Altman plots revealed that compared with FFR, the limits of agreement for single plane angioFFR were - 0.07 to 0.19 (mean difference 0.06, p = 0.002) and the limits of agreement for biplane FFR were - 0.09 to 0.15 (mean difference 0.03, p = 0.03). In conclusion, angioFFR calculated from single or biplane acquisitions by a biplane C-arm is feasible and may evolve to a tool for less invasive imaging-based assessment of myocardial ischemia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Isquemia Miocárdica / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Isquemia Miocárdica / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article