Your browser doesn't support javascript.
loading
Analysis and results from a UK national dose audit of paediatric CT examinations.
Worrall, Mark; Holubinka, Mike; Havariyoun, Glafkos; Hodgson, Kirsten; Edyvean, Sue; Holroyd, John; Davis, Anne; Dunn, Matthew; Gardiner, Anna.
Afiliação
  • Worrall M; NHS Tayside, Dundee, United Kingdom.
  • Holubinka M; Portsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.
  • Havariyoun G; King's College Hospital NHS Foundation Trust, London, United Kingdom.
  • Hodgson K; University Hospitals Birmingham NHS Foundation Trust, Birmingham, United Kingdom.
  • Edyvean S; Public Health England, London, United Kingdom.
  • Holroyd J; Public Health England, London, United Kingdom.
  • Davis A; Portsmouth Hospitals University NHS Trust, Portsmouth, United Kingdom.
  • Dunn M; Nottingham University Hospitals NHS Trust, London, United Kingdom.
  • Gardiner A; Cambridge University Hospitals NHS Foundation Trust, England, United Kingdom.
Br J Radiol ; 95(1129): 20210796, 2022 Jan 01.
Article em En | MEDLINE | ID: mdl-34767475
OBJECTIVE: To present the results following a UK national patient dose audit of paediatric CT examinations, to propose updated UK national diagnostic reference levels (DRLs) and to analyse current practice to see if any recommendations can be made to assist with optimisation. METHODS: A UK national dose audit was undertaken in 2019 focussing on paediatric CT examinations of the head, chest, abdomen/pelvis and cervical spine using the methods proposed by the International Commission on Radiological Protection. The audit pro-forma contained mandatory fields, of which the post-examination dosimetry (volume CT dose index and dose-length product) and the patient weight (for body examinations) were the most important. RESULTS: Analysis of the data submitted indicates that it is appropriate to propose national DRLs for CT head examinations in the 0-<1, 1-<5, 5-<10 and 10-<15 year age ranges. This extends the number of age categories of national DRLs from those at present and revises the existing values downwards. For CT chest examinations, it is appropriate to propose national DRLs for the first time in the UK for the 5-<15, 15-<30, 30-<50 and 50-<80 kg weight ranges. There were insufficient data received to propose national DRLs for abdomen/pelvis or cervical spine examinations. Recommendations towards optimisation focus on the use of tube current (mA) modulation, iterative reconstruction and the selection of examination tube voltage (kVp). CONCLUSION: Updated UK national DRLs are proposed for paediatric CT examinations of the head and chest. ADVANCES IN KNOWLEDGE: A national patient dose audit of paediatric CT examinations has led to the proposal of updated national DRLs.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Auditoria Médica Tipo de estudo: Guideline Limite: Adolescent / Child / Child, preschool / Humans / Infant País/Região como assunto: Europa Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Auditoria Médica Tipo de estudo: Guideline Limite: Adolescent / Child / Child, preschool / Humans / Infant País/Região como assunto: Europa Idioma: En Ano de publicação: 2022 Tipo de documento: Article