Your browser doesn't support javascript.
loading
Evaluation of coagulation with TEG in patients diagnosed COVID-19.
Vatansev, Hülya; Karaselek, Mehmet Ali; Yilmaz, Resül; Küççüktürk, Serkan; Topal, Ahmet; Yosunkaya, Sebnem; Küçük, Adem; Vatansev, Celalettin.
Afiliação
  • Vatansev H; Department of Chest Diseases, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Karaselek MA; Department of Internal Medicine, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Yilmaz R; Department of Anesthesiology and Reanimation, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Küççüktürk S; Department of Medical Biology, Medicine Faculty, Karamanoglu Mehmetbey Univesity, Karaman, Turkey.
  • Topal A; Department of Anesthesiology and Reanimation, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Yosunkaya S; Department of Chest Diseases, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Küçük A; Department of Internal Medicine, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
  • Vatansev C; Department of General Surgery, Meram Medicine Faculty, Necmettin Erbakan University, Konya, Turkey.
Turk J Med Sci ; 52(1): 1-10, 2022 Feb.
Article em En | MEDLINE | ID: mdl-34773688
ABSTRACT

BACKGROUND:

A high D-dimer level may indicate the risk of coagulopathy and mortality in COVID-19 patients. T hromboelastography (TEG) is a test that evaluates clot formation and fibrinolysis in real-time, unlike routine coagulation tests. The study aimed to investigate the coagulation process with TEG in patients diagnosed with COVID-19.

METHODS:

The study was performed at our university hospital, chest diseases outpatient clinic as a cross-section study. A total of 51 patients with 23 high D-dimer levels group (HDG) and 28 low D-dimers group (LDG) were included in the study. TEG analysis was performed at the pretreatment evaluation in these two groups.

RESULTS:

D-dimer and fibrinogen levels of the HDG were higher than those of the LDG (550 vs. 90 ng/mL, p < 0.001; 521 vs. 269 mg/ dL, p < 0.001, respectively). In TEG analysis, HDG's R and K values were lower than LDG, and HDG's Angle, MA, and CI values were higher than LDG (p = 0.037; p < 0.001; p < 0.001; p < 0.001; p < 0.001, respectively). ROC curve analysis suggested that the optimum TEG parameters cut-off points for thrombosis risk were as below for K was ≤2.1 min, for R was ≤6.1 min, for Angle was >62°, MA was 60.4 mm.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tromboelastografia / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tromboelastografia / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article