Investigation of the effect of a 15-degree tilt-in-space on the fluctuation of shear forces exerted on the buttocks when the back support is reclined.
Kobara, Kenichi; Nagata, Yasuyuki; Fujita, Daisuke; Takahashi, Hisashi; Osaka, Hiroshi; Suehiro, Tadanobu.
Afiliação
  • Kobara K; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Nagata Y; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Fujita D; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Takahashi H; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Osaka H; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Suehiro T; Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare: 288 Matsushima, Kurashiki, Okayama 701-0193, Japan.
J Phys Ther Sci ; 33(11): 838-844, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34776619
[Purpose] This study aimed to investigate the effect of the combination of 15° tilt-in-space and recline angles on the fluctuation of shear forces exerted on the buttocks. [Participants and Methods] The participants were 11 healthy adult males. The parameters of the shear forces were the parallel and perpendicular forces exerted on the buttocks as measured by a force plate. The two conditions tested were T0R100-130 and T15R100-130. The tilt-in-space angles were set to 0° and 15° in the T0R100-130 and T15R100-130 conditions, respectively. The reclining angles were determined to be 100° to 130° in both conditions. [Results] Upon comparing the two conditions, the parallel and the perpendicular forces exerted on the buttocks in the T15R100-130 condition were significantly lower than those in the T0R100-130 condition in all positions of back support. Upon comparing the fluctuation values of the parallel and perpendicular forces, those applied in the T15R100-130 condition were significantly higher than those in the T0R100-130 condition. [Conclusion] These results suggest that the fluctuation of shear forces exerted on the buttocks could be decreased by using a combination of 15° tilt-in-space and reclining functions.