Your browser doesn't support javascript.
loading
Comparison of ROX and HACOR scales to predict high-flow nasal cannula failure in patients with SARS-CoV-2 pneumonia.
Valencia, Carlos Fernando; Lucero, Oscar David; Castro, Onofre Casas; Sanko, Andrey Alexandrovich; Olejua, Peter Alfonso.
Afiliação
  • Valencia CF; Emergency Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Carrera 7 No. 40-62, Bogotá, Colombia.
  • Lucero OD; Internal Medicine Resident, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Carrera 7 No. 40-62, Bogotá, Colombia. Oscardavidlucero21@gmail.com.
  • Castro OC; Emergency Medicine Resident, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Carrera 7 No. 40-62, Bogotá, Colombia.
  • Sanko AA; General Medicine, Pontificia Universidad Javeriana, Carrera 7 No. 40-62, Bogotá, Colombia.
  • Olejua PA; Epidemiology Department, Pontificia Universidad Javeriana, Carrera 7 No. 40-62, Bogotá, Colombia.
Sci Rep ; 11(1): 22559, 2021 11 19.
Article em En | MEDLINE | ID: mdl-34799658
ABSTRACT
The pandemic of SARSCov2 infection has created a challenge in health services worldwide. Some scales have been applied to evaluate the risk of intubation, such as the ROX and HACOR. The objective of this study is to compare the predictive capacity of the HACOR scale and the ROX index and define the optimal cut-off points. Study of diagnostic tests based on a retrospective cohort. Composite outcome was the proportion of patients that needed endotracheal intubation (ETI) or died of COVID19 pneumonia. Discrimination capacity was compared by the area under the curve of each of the two scales and the optimal cut-off point was determined using the Liu method. 245 patients were included, of which 140 (57%) required ETI and 152 (62%) had the composite end result of high-flow nasal cannula (HFNC) failure. The discrimination capacity was similar for the two scales with an area under receiver operating characteristic curve of 0.71 and 0.72 for the HACOR scale for the ROX index, respectively. The optimal cut-off point for the ROX index was 5.6 (sensitivity 62% specificity 65%), while the optimal cut-off point for the HACOR scale was 5.5 (sensitivity 66% specificity 65%). The HACOR scale and the ROX index have a moderate predictive capacity to predict failures to the HFNC strategy. They can be used in conjunction with other clinical variables to define which patients may require invasive mechanical ventilation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cateterismo / COVID-19 Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cateterismo / COVID-19 Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article