Your browser doesn't support javascript.
loading
A dynamic collimation and alignment system for the Helmholtz linear accelerator.
Lauber, S; Aulenbacher, K; Barth, W; Basten, M; Burandt, C; Dziuba, F; Forck, P; Gettmann, V; Heilmann, M; Kürzeder, T; List, J; Miski-Oglu, M; Podlech, H; Rubin, A; Schwarz, M; Sieber, T; Yaramyshev, S.
Afiliação
  • Lauber S; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Aulenbacher K; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Barth W; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Basten M; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Burandt C; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Dziuba F; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Forck P; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
  • Gettmann V; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
  • Heilmann M; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
  • Kürzeder T; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • List J; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Miski-Oglu M; Helmholtz Institute Mainz, Mainz 55128, Germany.
  • Podlech H; IAP, Goethe University Frankfurt, Frankfurt 60438, Germany.
  • Rubin A; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
  • Schwarz M; IAP, Goethe University Frankfurt, Frankfurt 60438, Germany.
  • Sieber T; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
  • Yaramyshev S; GSI Helmholtz Center for Heavy Ion Research, Darmstadt 64291, Germany.
Rev Sci Instrum ; 92(11): 113306, 2021 Nov 01.
Article em En | MEDLINE | ID: mdl-34852560
ABSTRACT
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article