Your browser doesn't support javascript.
loading
Cold-induced phase separation for the simple and reliable extraction of sex hormones for subsequent LC-MS/MS analysis.
Peng, Rui; Le, Juan; Yang, Shu-Lin; Cheng, Jing-Ru; Li, Yan; Wang, Shao-Ting.
Afiliação
  • Peng R; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Le J; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Yang SL; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Cheng JR; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Li Y; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Wang ST; Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China. Electronic address: shaotingw@whu.edu.cn.
J Lipid Res ; 63(1): 100158, 2022 01.
Article em En | MEDLINE | ID: mdl-34863861
Sex hormones, including androgens, estrogens, and progestogens, are important biomarkers for various diseases. Quantification of sex hormones is typically conducted by LC-MS/MS. At present, most methods require liquid-liquid extraction or solid phase extraction for sample preparation. However, these pretreatments are prone to compromise LC-MS/MS throughput. To improve on the current standard practices, we investigated cold-induced phase separation for sex hormone extraction. After protein precipitation with acetonitrile and adjusting the solution constitution with water, samples were stored at -30°C for 10 min to generate two distinct phases: an acetonitrile-rich layer on top of a water-rich layer. During this process, the hydrophobic sex hormones spontaneously separate into the upper layer. This simple and reliable cold-induced phase separation-based LC-MS/MS methodology was used here to simultaneously detect estrone, estradiol, estriol, testosterone, androstenedione, dehydroepiandrosterone, progesterone, and 17-hydroxyprogesterone in serum. Validation of this method indicated satisfactory performance, including acceptable linearity, accuracy, precision, and tractability. Compared with the mainstream liquid-liquid extraction-based method, this new method exhibits significant progress in throughput, which shortens the time cost of sample preparation from 90 to 40 min. We propose that this method can be an excellent alternative for sex hormone analysis in routine clinical laboratories.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hormônios Esteroides Gonadais Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hormônios Esteroides Gonadais Idioma: En Ano de publicação: 2022 Tipo de documento: Article