Your browser doesn't support javascript.
loading
Computer-Aided Diagnosis of Gastrointestinal Ulcer and Hemorrhage Using Wireless Capsule Endoscopy: Systematic Review and Diagnostic Test Accuracy Meta-analysis.
Bang, Chang Seok; Lee, Jae Jun; Baik, Gwang Ho.
Afiliação
  • Bang CS; Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Republic of Korea.
  • Lee JJ; Institute for Liver and Digestive Diseases, Hallym University, Chuncheon, Republic of Korea.
  • Baik GH; Institute of New Frontier Research, Hallym University College of Medicine, Chuncheon, Republic of Korea.
J Med Internet Res ; 23(12): e33267, 2021 12 14.
Article em En | MEDLINE | ID: mdl-34904949
ABSTRACT

BACKGROUND:

Interpretation of capsule endoscopy images or movies is operator-dependent and time-consuming. As a result, computer-aided diagnosis (CAD) has been applied to enhance the efficacy and accuracy of the review process. Two previous meta-analyses reported the diagnostic performance of CAD models for gastrointestinal ulcers or hemorrhage in capsule endoscopy. However, insufficient systematic reviews have been conducted, which cannot determine the real diagnostic validity of CAD models.

OBJECTIVE:

To evaluate the diagnostic test accuracy of CAD models for gastrointestinal ulcers or hemorrhage using wireless capsule endoscopic images.

METHODS:

We conducted core databases searching for studies based on CAD models for the diagnosis of ulcers or hemorrhage using capsule endoscopy and presenting data on diagnostic performance. Systematic review and diagnostic test accuracy meta-analysis were performed.

RESULTS:

Overall, 39 studies were included. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of ulcers (or erosions) were .97 (95% confidence interval, .95-.98), .93 (.89-.95), .92 (.89-.94), and 138 (79-243), respectively. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of hemorrhage (or angioectasia) were .99 (.98-.99), .96 (.94-0.97), .97 (.95-.99), and 888 (343-2303), respectively. Subgroup analyses showed robust results. Meta-regression showed that published year, number of training images, and target disease (ulcers vs erosions, hemorrhage vs angioectasia) was found to be the source of heterogeneity. No publication bias was detected.

CONCLUSIONS:

CAD models showed high performance for the optical diagnosis of gastrointestinal ulcer and hemorrhage in wireless capsule endoscopy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Endoscopia por Cápsula Tipo de estudo: Diagnostic_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Endoscopia por Cápsula Tipo de estudo: Diagnostic_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article