Your browser doesn't support javascript.
loading
Spatiotemporal Measurement of Arterial Pulse Waves Enabled by Wearable Active-Matrix Pressure Sensor Arrays.
Baek, Sanghoon; Lee, Youngoh; Baek, JinHyeok; Kwon, Jimin; Kim, Seongju; Lee, Seungjae; Strunk, Karl-Philipp; Stehlin, Sebastian; Melzer, Christian; Park, Sung-Min; Ko, Hyunhyub; Jung, Sungjune.
Afiliação
  • Baek S; Department of Convergence IT Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Republic of Korea.
  • Lee Y; School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology, Ulsan Metropolitan City 44919, Republic of Korea.
  • Baek J; Department of Convergence IT Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Republic of Korea.
  • Kwon J; Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States.
  • Kim S; Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Republic of Korea.
  • Lee S; School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology, Ulsan Metropolitan City 44919, Republic of Korea.
  • Strunk KP; InnovationLab GmbH, Speyerer Straße 4, 69115 Heidelberg, Germany.
  • Stehlin S; InnovationLab GmbH, Speyerer Straße 4, 69115 Heidelberg, Germany.
  • Melzer C; InnovationLab GmbH, Speyerer Straße 4, 69115 Heidelberg, Germany.
  • Park SM; Department of Convergence IT Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Republic of Korea.
  • Ko H; School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology, Ulsan Metropolitan City 44919, Republic of Korea.
  • Jung S; Department of Convergence IT Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Republic of Korea.
ACS Nano ; 16(1): 368-377, 2022 Jan 25.
Article em En | MEDLINE | ID: mdl-34910466
Wearable pressure sensors have demonstrated great potential in detecting pulse pressure waves on the skin for the noninvasive and continuous diagnosis of cardiac conditions. However, difficulties lie in positioning conventional single-point sensors on an invisible arterial line, thereby preventing the detection of adequate signal amplitude for accurate pulse wave analysis. Herein, we introduce the spatiotemporal measurements of arterial pulse waves using wearable active-matrix pressure sensors to obtain optimal pulse waveforms. We fabricate thin-film transistor (TFT) arrays with high yield and uniformity using inkjet printing where array sizes can be customizable and integrate them with highly sensitive piezoresistive sheets. We maximize the pressure sensitivity (16.8 kPa-1) and achieve low power consumption (101 nW) simultaneously by strategically modulating the TFT operation voltage. The sensor array creates a spatiotemporal pulse wave map on the wrist. The map presents the positional dependence of pulse amplitudes, which allows the positioning of the arterial line to accurately extract the augmentation index, a parameter for assessing arterial stiffness. The device overcomes the positional inaccuracy of conventional single-point sensors, and therefore, it can be used for medical applications such as arterial catheter injection or the diagnosis of cardiovascular disease in daily life.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Cardiovasculares / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Cardiovasculares / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article