Assessment of Tacrolimus Neurotoxicity Measured by Retinal OCT.
Mousavi Ahmadian, Kazem; Serra Cabañas, Núria; Cordoba Herrera, Christian; Fayos de Arizon, Leonor; Perez Mir, Mónica; Guirado Perich, Lluís; Facundo Molas, Carme.
Afiliação
  • Mousavi Ahmadian K; Centre Ocular Quirúrgic de Terrassa, Terrassa, Spain; Servicio Oftalmología, Unidad de Retina, Hospital Universitari de Vic, Vic, Spain; Facultat de Medicina, Universitat de Vic - Universitat Central Catalunya, Vic, Spain.
  • Serra Cabañas N; Servei Nefrologia, Fundació Puigvert, Barcelona, Spain; Servei Nefrologia Fundació Puigvert, Institutuo de Investigaciones Biomédicas Sant Pau (IIB-Sant Pau), Departamento de Medicina-Universitat Autònoma de Barcelona, REDin REN, Instituto de Investigación Carlos III, Barcelona, Spain.
  • Cordoba Herrera C; Servei Nefrologia, Fundació Puigvert, Barcelona, Spain; Servei Nefrologia Fundació Puigvert, Institutuo de Investigaciones Biomédicas Sant Pau (IIB-Sant Pau), Departamento de Medicina-Universitat Autònoma de Barcelona, REDin REN, Instituto de Investigación Carlos III, Barcelona, Spain.
  • Fayos de Arizon L; Servei Nefrologia, Fundació Puigvert, Barcelona, Spain; Servei Nefrologia Fundació Puigvert, Institutuo de Investigaciones Biomédicas Sant Pau (IIB-Sant Pau), Departamento de Medicina-Universitat Autònoma de Barcelona, REDin REN, Instituto de Investigación Carlos III, Barcelona, Spain.
  • Perez Mir M; Centre Ocular Quirúrgic de Terrassa, Terrassa, Spain; Servicio Oftalmología, Unidad de Retina, Hospital Universitari de Vic, Vic, Spain; Facultat de Medicina, Universitat de Vic - Universitat Central Catalunya, Vic, Spain; Servei Nefrologia, Fundació Puigvert, Barcelona, Spain; Servei Nefrologia Fun
  • Guirado Perich L; Facultat de Medicina, Universitat de Vic - Universitat Central Catalunya, Vic, Spain; Servei Nefrologia, Fundació Puigvert, Barcelona, Spain; Servei Nefrologia Fundació Puigvert, Institutuo de Investigaciones Biomédicas Sant Pau (IIB-Sant Pau), Departamento de Medicina-Universitat Autònoma de Barcel
  • Facundo Molas C; Facultat de Medicina, Universitat de Vic - Universitat Central Catalunya, Vic, Spain. Electronic address: carmef@hotmail.com.
Transplant Proc ; 54(1): 80-86, 2022.
Article em En | MEDLINE | ID: mdl-34911620
ABSTRACT

BACKGROUND:

Neurotoxicity secondary to anticalcineurinics is a prevalent side effect in transplant recipients. Optical coherence tomography (OCT) scans the central nervous system by direct access to the retina. OCT assesses central nervous system involvement by measuring the thickness of the retinal layers, especially the ganglion cell layer (GCL). The retinal scan divides the scanned area into affected and unaffected segments, which can be quantified for each eye. The aim of this study was to determine retinal GCL thickness by means of OCT, analyzing the proportion of affected segments in individuals exposed to tacrolimus compared with a control group. MATERIALS AND

METHODS:

We evaluated 20 renal transplant recipients exposed to tacrolimus for ≥6 months. The number of affected segments in the GCL of the retina was quantified by OCT. The control group was drawn from the general population attending routine ophthalmologic checkups.

RESULTS:

Patients exposed to tacrolimus had a pathologic examination in 50% of cases compared with 20% in the control group (P < .044). Furthermore, among patients with an exposure time to tacrolimus >5 years, the examination was pathologic in 80% (P < .005). Linear regression analysis showed the presence of GCL segments with decreased thickness to be associated with the duration of exposure to tacrolimus (P = .036) and the time in dialysis before kidney transplant (P = .030).

CONCLUSION:

Although this is a preliminary study, OCT scanning could serve to detect the neurotoxic effect of tacrolimus on the retinal GCL and central nervous system in renal transplant recipients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tacrolimo / Tomografia de Coerência Óptica Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tacrolimo / Tomografia de Coerência Óptica Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article