ABSTRACT

BACKGROUND:

Volumetric modulated arc therapy (VMAT) planning is a time-consuming process of radiation therapy. With a deep learning approach, 3D dose distribution can be predicted without the need for an actual dose calculation. This approach can accelerate the process by guiding and confirming the achievable dose distribution in order to reduce the replanning iterations while maintaining the plan quality.

METHODS:

In this study, three dose distribution predictive models of VMAT for prostate cancer were developed, evaluated, and compared. Each model was designed with a different input data structure to train and test the model (1) patient CT alone (PCT alone), (2) patient CT and generalized organ structure (PCTGOS), and (3) patient CT and specific organ structure (PCTSOS). The generative adversarial network (GAN) model was used as a core learning algorithm. The models were trained slice-by-slice using 46 VMAT plans for prostate cancer, and then used to predict and evaluate the dose distribution from 8 independent plans.

RESULTS:

VMAT dose distribution was generated with a mean prediction time of approximately 3.5 s per patient, whereas the PCTSOS model was excluded due to a mean prediction time of approximately 17.5 s per patient. The highest average 3D gamma passing rate was 80.51 ± 5.94, while the lowest overall percentage difference of dose-volume histogram (DVH) parameters was 6.01 ± 5.44% for the prescription dose from the PCTGOS model. However, the PCTSOS model was the most reliable for the evaluation of multiple parameters.

CONCLUSIONS:

This dose prediction model could accelerate the iterative optimization process for the planning of VMAT treatment by guiding the planner with the desired dose distribution.