Your browser doesn't support javascript.
loading
UiO-66 Selective Enrichment Integrated with Thermal Desorption GC-MS for Detection of Benzene Homologues in Ambient Air.
Lin, Xing-Tao; Sun, Ge; Zhao, Jing-Qiang; Tang, Ling-Li; Li, Sheng-Hua; Xie, Ya-Bo.
Afiliação
  • Lin XT; Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
  • Sun G; Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
  • Zhao JQ; Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
  • Tang LL; Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
  • Li SH; School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Xie YB; Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
J Anal Methods Chem ; 2021: 3138436, 2021.
Article em En | MEDLINE | ID: mdl-34950524
ABSTRACT
In this study, UiO-66 was selected as sorbent media packed in the tube to selectively enrich trace levels of benzene homologues such as benzene, toluene, and xylene (BTX) in ambient air prior to thermal desorption (TD)-GC-MS determination. A series of experiments were conducted to obtain the optimal TD conditions. The results indicated that the optimal TD parameters were as follows desorption temperature of 180°C, desorption flow rate of 50 mL min-1, and desorption time of 30 min. Furthermore, the method based on UiO-66 enrichment integrated with TD-GC-MS for trace levels of BTX was successfully developed. It exhibited a good linearity (R 2 > 0.99) in the range of 50-1000 ng, except for p, m-xylene in the range of 100-2000 ng, and achieved the recovery of 69.4-101.3%, and the relative standard deviation of 3.8-6.4%. The detection limits of BTX were 1.6-4.0 ng; according to 10 L of sampling volume, the method detection limits would be in the range of 0.16-0.40 µg m-3. Additionally, the method was successfully applied to determine BTX in indoor air and showed good selectivity and sensitivity. In summary, the findings in this work revealed that UiO-66 was an attractive adsorbent for selective enrichment trace levels of BTX compounds in ambient air, which was favorable for the subsequent detection by TD-GC-MS.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article