Your browser doesn't support javascript.
loading
Biochemical testing for the diagnosis of Wilson's disease: A systematic review.
Salman, Hafiz Muhammad; Amin, Mahwish; Syed, Javaria; Sarfraz, Zouina; Sarfraz, Azza; Sarfraz, Muzna; Farfán Bajaña, Maria Jose; Felix, Miguel; Cherrez-Ojeda, Ivan.
Afiliação
  • Salman HM; Services Institute of Medical Sciences, Lahore, Pakistan.
  • Amin M; Sir Ganga Ram Hospital, Lahore, Punjab, Pakistan.
  • Syed J; Sargodha Medical College, Sargodha, Pakistan.
  • Sarfraz Z; Fatima Jinnah Medical University, Lahore, Pakistan.
  • Sarfraz A; The Aga Khan University, Karachi, Pakistan.
  • Sarfraz M; King Edward Medical University, Lahore, Pakistan.
  • Farfán Bajaña MJ; Universidad Espíritu Santo, Samborondón, Ecuador.
  • Felix M; Respiralab, Respiralab Research Group, Guayaquil, Ecuador.
  • Cherrez-Ojeda I; Universidad Espíritu Santo, Samborondón, Ecuador.
J Clin Lab Anal ; 36(2): e24191, 2022 Feb.
Article em En | MEDLINE | ID: mdl-34951059
BACKGROUND: Wilson's disease (WD) is a rare inherited disorder that leads to copper accumulation in the liver, brain, and other organs. WD is prevalent worldwide, with an occurrence of 1 per 30,000 live births. Currently, there is no gold standard diagnostic test for WD. The objective of this systematic review is to determine the diagnostic accuracy for WD of three biochemical tests, namely hepatic copper, 24-hour urinary copper, and ceruloplasmin using the Leipzig criteria. METHODS: Adhering to PRISMA guidelines, databases including PubMed/MEDLINE, CINAHL Plus, Web of Science, and Cochrane were searched. Studies that comprised of confirmed or suspected WD along with normal populations were included with adult and pediatric group. The sensitivity, specificity, negative predictive value and positive predictive value were computed using RevMan 5.4. RESULTS: Nine studies were included. The best practice evidence for 24-hour urinary copper test ranged from a cutoff value of 0.64-1.6 µmol/24 h (N = 268; sensitivity = 75.6%, specificity = 98.3%). Hepatic copper test was optimally cutoff based on the ROC curve analysis at 1.2 µmol/g yielding a power of 96.4% sensitivity and 95.4% specificity (N = 1,150); however, the tried and tested 4 µmol/g cutoff, with 99.4% sensitivity and 96.1% specificity, is more widely accepted. The ceruloplasmin test cutoff value was found to be ranging from 0.14 to 0.2 g/L (N = 4,281; sensitivity = 77.1%-99%, specificity = 55.9%-82.8%). CONCLUSION: This paper provides a large-scale analysis of current evidence pertaining to the biochemical diagnosis of WD employing the Leipzig criteria. The laboratory values are typically based on specific subgroups based on age, ethnicity, and clinical subgroups. The findings of this systematic review must be used with caution, given the over- or under-estimation of the index tests.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ceruloplasmina / Cobre / Degeneração Hepatolenticular / Fígado Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ceruloplasmina / Cobre / Degeneração Hepatolenticular / Fígado Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article