Your browser doesn't support javascript.
loading
Axillary vein catheterization using ultrasound guidance: A prospective randomized cross-over controlled simulation comparing standard ultrasound and new needle-pilot device.
Boulet, Nicolas; Bobbia, Xavier; Gavoille, Antoine; Louart, Benjamin; Lefrant, Jean Yves; Roger, Claire; Muller, Laurent.
Afiliação
  • Boulet N; Intensive Care Unit, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
  • Bobbia X; EA 2992 IMAGINE, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
  • Gavoille A; Department of Biostatistics-Bioinformatic, Hospices Civils de Lyon, Lyon, France.
  • Louart B; Intensive Care Unit, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
  • Lefrant JY; Intensive Care Unit, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
  • Roger C; Intensive Care Unit, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
  • Muller L; Intensive Care Unit, Department of Anesthesiology, Critical Care, Pain and Emergency Medicine, Nîmes University Hospital, Nîmes, France.
J Vasc Access ; 24(5): 1042-1050, 2023 Sep.
Article em En | MEDLINE | ID: mdl-34965763
ABSTRACT

BACKGROUND:

Real-time ultrasound (US) guidance facilitates central venous catheterization in intensive care unit (ICU). New magnetic needle-pilot devices could improve efficiency and safety of central venous catheterization. This simulation trial was aimed at comparing venipuncture with a new needle-pilot device to conventional US technique.

METHODS:

In a prospective, randomized, simulation trial, 51 ICU physicians and residents cannulated the right axillary vein of a human torso mannequin with standard US guidance and with a needle-pilot system, in a randomized order. The primary outcome was the time from skin puncture to successful venous cannulation. The secondary outcomes were the number of skin punctures, the number of posterior wall puncture of the axillary vein, the number of arterial punctures, the number of needle redirections, the failure rate, and the operator comfort.

RESULTS:

Time to successful cannulation was shorter with needle-pilot US-guided technique (22 s (interquartile range (IQR) = 16-42) vs 25 s (IQR = 19-128); median of difference (MOD) = -9 s (95%-confidence interval (CI) -5, -22), p < 0.001). The rates of skin punctures, posterior wall puncture of axillary vein, and needle redirections were also lower (p < 0.01). Comfort was higher in needle-pilot US-guided group on a 11-points numeric scale (8 (IQR = 8-9) vs 6 (IQR = 6-8), p < 0.001).

CONCLUSIONS:

In a simulation model, US-guided axillary vein catheterization with a needle-pilot device was associated with a shorter time of successful cannulation and a decrease in numbers of skin punctures and complications. The results plea for investigating clinical performance of this new device.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Axilar / Cateterismo Venoso Central Tipo de estudo: Clinical_trials / Guideline / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Axilar / Cateterismo Venoso Central Tipo de estudo: Clinical_trials / Guideline / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article