Your browser doesn't support javascript.
loading
Progressive Microstructural Deterioration Dictates Evolving Biomechanical Dysfunction in the Marfan Aorta.
Cavinato, Cristina; Chen, Minghao; Weiss, Dar; Ruiz-Rodríguez, Maria Jesús; Schwartz, Martin A; Humphrey, Jay D.
Afiliação
  • Cavinato C; Department of Biomedical Engineering, Yale University, New Haven, CT, United States.
  • Chen M; Cardiovascular Research Center and Department of Internal Medicine (Cardiology), Yale School of Medicine, New Haven, CT, United States.
  • Weiss D; Department of Biomedical Engineering, Yale University, New Haven, CT, United States.
  • Ruiz-Rodríguez MJ; Centro Nacional de Investigaciones Cardiovasculares (CNIC) and Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain.
  • Schwartz MA; Department of Biomedical Engineering, Yale University, New Haven, CT, United States.
  • Humphrey JD; Cardiovascular Research Center and Department of Internal Medicine (Cardiology), Yale School of Medicine, New Haven, CT, United States.
Front Cardiovasc Med ; 8: 800730, 2021.
Article em En | MEDLINE | ID: mdl-34977201
ABSTRACT
Medial deterioration leading to thoracic aortic aneurysms arises from multiple causes, chief among them mutations to the gene that encodes fibrillin-1 and leads to Marfan syndrome. Fibrillin-1 microfibrils associate with elastin to form elastic fibers, which are essential structural, functional, and instructional components of the normal aortic wall. Compromised elastic fibers adversely impact overall structural integrity and alter smooth muscle cell phenotype. Despite significant progress in characterizing clinical, histopathological, and mechanical aspects of fibrillin-1 related aortopathies, a direct correlation between the progression of microstructural defects and the associated mechanical properties that dictate aortic functionality remains wanting. In this paper, age-matched wild-type, Fbn1 C1041G/+, and Fbn1 mgR/mgR mouse models were selected to represent three stages of increasing severity of the Marfan aortic phenotype. Ex vivo multiphoton imaging and biaxial mechanical testing of the ascending and descending thoracic aorta under physiological loading conditions demonstrated that elastic fiber defects, collagen fiber remodeling, and cell reorganization increase with increasing dilatation. Three-dimensional microstructural characterization further revealed radial patterns of medial degeneration that become more uniform with increasing dilatation while correlating strongly with increased circumferential material stiffness and decreased elastic energy storage, both of which comprise aortic functionality.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article