Your browser doesn't support javascript.
loading
Multi-loop traction device facilitates gastric endoscopic submucosal dissection: ex vivo pilot study and an inaugural clinical experience.
Matsui, Hiroaki; Tamai, Naoto; Futakuchi, Toshiki; Kamba, Shunsuke; Dobashi, Akira; Sumiyama, Kazuki.
Afiliação
  • Matsui H; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan.
  • Tamai N; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan. tamai-naoto@jikei.ac.jp.
  • Futakuchi T; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan.
  • Kamba S; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan.
  • Dobashi A; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan.
  • Sumiyama K; Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishi Shinbashi, Minato-ku, Tokyo, 105-8461, Japan.
BMC Gastroenterol ; 22(1): 10, 2022 Jan 06.
Article em En | MEDLINE | ID: mdl-34991489
ABSTRACT

BACKGROUND:

Endoscopic submucosal dissection (ESD) is technically difficult and requires considerable training. The authors have developed a multi-loop traction device (MLTD), a new traction device that offers easy attachment and detachment. We aimed to evaluate the utility of MLTD in ESD.

METHODS:

This ex vivo pilot study was a prospective, block-randomized, comparative study of a porcine stomach model. Twenty-four lesions were assigned to a group that undertook ESD using the MLTD (M-ESD group) and a group that undertook conventional ESD (C-ESD group) to compare the speed of submucosal dissection. In addition, the data of consecutive 10 patients with eleven gastric lesions was collected using electronic medical records to clarify the inaugural clinical outcomes of gastric ESD using MLTD.

RESULTS:

The median (interquartile range) speed of submucosal dissection in the M-ESD and C-ESD groups were 141.5 (60.9-177.6) mm2/min and 35.5 (20.8-52.3) mm2/min, respectively; submucosal dissection was significantly faster in the M-ESD group (p < 0.05). The rate of en bloc resection and R0 resection was 100% in both groups, and there were no perforation in either group. The MLTD attachment time was 2.5 ± 0.9 min and the MLTD extraction time was 1.0 ± 1.1 min. Clinical outcomes of MLTD in gastric ESD were almost the same as those of ex vivo pilot study.

CONCLUSIONS:

MLTD increased the speed of submucosal dissection in ESD and was similarly effective when used by expert and trainee endoscopists without perforation. MLTD can potentially ensure a safer and faster ESD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ressecção Endoscópica de Mucosa Tipo de estudo: Clinical_trials / Observational_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ressecção Endoscópica de Mucosa Tipo de estudo: Clinical_trials / Observational_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article