Your browser doesn't support javascript.
loading
Augmented reality-assisted localization of solitary pulmonary nodules for precise sublobar lung resection: a preliminary study using an animal model.
Peng, Mingzheng; Yu, Lingming; Zhou, Yang; Yang, Yunhai; Luo, Qingquan; Cheng, Xinghua.
Afiliação
  • Peng M; Shanghai Lung Tumor Clinical Medical Center, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Yu L; Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Zhou Y; Department of Equipment, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Yang Y; Shanghai Lung Tumor Clinical Medical Center, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Luo Q; Shanghai Lung Tumor Clinical Medical Center, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Cheng X; Shanghai Lung Tumor Clinical Medical Center, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
Transl Lung Cancer Res ; 10(11): 4174-4184, 2021 Nov.
Article em En | MEDLINE | ID: mdl-35004248
ABSTRACT

BACKGROUND:

Accurate localization of early lung cancer, manifested as solitary pulmonary nodules (SPNs) on computed tomography (CT), is critical in sublobar lung resection. The AR-assisted localization of SPNs was evaluated using a pig animal model.

METHODS:

A Microsoft HoloLens AR system was used. First, a plastic thoracic model was used for the pilot study. Three female 12 months 45 kg Danish Landrace Pigs were then used for the animal study. Thirty natural pulmonary structures, such as lymphonodus and bifurcated bronchioles or bronchial vessels, were chosen as simulated SPNs. The average angle between the actual puncturing needle and the expected path, the average distance between the puncture point and the plan point, and the difference between the actual puncturing depth and expected depth were recorded, and the accuracy rate was calculated.

RESULTS:

The point selected in the plastic thoracic model could be hit accurately with the assistance from the AR system in the pilot study. Moreover, the average angle between the actual puncturing needle and the expected path was 14.52°±6.04°. Meanwhile, the average distance between the puncture point and the expected point was 8.74±5.07 mm, and the difference between the actual and expected depths was 9.42±7.95 mm. Puncturing within a 1 cm3 area around the SPN using a hook-wire was considered a successful hit. The puncture accuracy was calculated. The average hit rate within a spherical area with a diameter of 1 cm range was 76.67%, and within a diameter of 2 cm range was 100%.

CONCLUSIONS:

The HoloLens AR-assisted localization of SPNs may become a promising technique to improve the surgical treatment of early-stage lung cancer. Here, we evaluated its feasibility in an animal model. Nevertheless, its safety and effectiveness require further investigation in clinical trials.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article