Your browser doesn't support javascript.
loading
Dataset of propylene carbonate based liquid electrolyte mixtures for sodium-ion cells.
Hofmann, Andreas; Wang, Zhengqi; Bautista, Sebastian Pinto; Weil, Marcel; Müller, Freya; Löwe, Robert; Schneider, Luca; Mohsin, Ijaz Ul; Hanemann, Thomas.
Afiliação
  • Hofmann A; Karlsruher Institut für Technologie, Institut für Angewandte Materialien (IAM), Herrmann-von-Helmholtz Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
  • Wang Z; Karlsruher Institut für Technologie, Institut für Angewandte Materialien (IAM), Herrmann-von-Helmholtz Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
  • Bautista SP; Department of Microsystems Engineering, University of Freiburg, Georges-Köhler-Allee 102, Freiburg D-79110, Germany.
  • Weil M; Karlsruher Institut für Technologie, Institut für Technikfolgenabschätzung und Systemanalyse (ITAS), Postfach 3640, Karlsruhe 76021, Germany.
  • Müller F; Helmholtz-Institut Ulm für Elektrochemische Energiespeicherung (HIU), Helmholtzstraße 11, Ulm 89081, Germany.
  • Löwe R; Karlsruher Institut für Technologie, Institut für Technikfolgenabschätzung und Systemanalyse (ITAS), Postfach 3640, Karlsruhe 76021, Germany.
  • Schneider L; Karlsruher Institut für Technologie, Institut für Angewandte Materialien (IAM), Herrmann-von-Helmholtz Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
  • Mohsin IU; Karlsruher Institut für Technologie, Institut für Angewandte Materialien (IAM), Herrmann-von-Helmholtz Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
  • Hanemann T; Karlsruher Institut für Technologie, Institut für Angewandte Materialien (IAM), Herrmann-von-Helmholtz Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
Data Brief ; 40: 107775, 2022 Feb.
Article em En | MEDLINE | ID: mdl-35028347
ABSTRACT
In this manuscript, we present rheology, ionic conductivity, density, chromatography, and life cycle analysis data on the PC+X electrolyte system with and without LiClO4. In particular, the data are presented in contact with Na surfaces. In this case, photographic images of electrolyte-sodium mixtures are also shown. The data was analyzed using OriginPro software to visualize it in an appropriate manner. In our view, the data serve as comparative values, form a basis of a chromatography analysis and are also valuable for modeling. The analysis of the data is presented in the manuscript "Comprehensive characterization of propylene carbonate based liquid electrolyte mixtures for sodium-ion cells" [1].
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article