Your browser doesn't support javascript.
loading
Hyperspectral Counting of Multiplexed Nanoparticle Emitters in Single Cells and Organelles.
Jena, Prakrit V; Gravely, Mitchell; Cupo, Christian; Safaee, Mohammad Moein; Roxbury, Daniel; Heller, Daniel A.
Afiliação
  • Jena PV; Memorial Sloan Kettering Cancer Center, New York, New York 10065, United States.
  • Gravely M; Department of Chemical Engineering, University of Rhode Island, Kingston, Rhode Island 02881, United States.
  • Cupo C; Memorial Sloan Kettering Cancer Center, New York, New York 10065, United States.
  • Safaee MM; Department of Chemical Engineering, University of Rhode Island, Kingston, Rhode Island 02881, United States.
  • Roxbury D; Department of Chemical Engineering, University of Rhode Island, Kingston, Rhode Island 02881, United States.
  • Heller DA; Memorial Sloan Kettering Cancer Center, New York, New York 10065, United States.
ACS Nano ; 16(2): 3092-3104, 2022 02 22.
Article em En | MEDLINE | ID: mdl-35049273
ABSTRACT
Nanomaterials are the subject of a range of biomedical, commercial, and environmental investigations involving measurements in living cells and tissues. Accurate quantification of nanomaterials, at the tissue, cell, and organelle levels, is often difficult, however, in part due to their inhomogeneity. Here, we propose a method that uses the distinct optical properties of a heterogeneous nanomaterial preparation in order to improve quantification at the single-cell and organelle level. We developed "hyperspectral counting", which employs diffraction-limited imaging via hyperspectral microscopy of a diverse set of fluorescent nanomaterials to estimate particle number counts in live cells and subcellular structures. A mathematical model was developed, and Monte Carlo simulations were employed, to improve the accuracy of these estimates, enabling quantification with single-cell and single-endosome resolution. We applied this nanometrology technique with single-walled carbon nanotubes and identified an upper limit of the rate of uptake into cells─approximately 3,000 nanotubes endocytosed within 30 min. In contrast, conventional region-of-interest counting results in a 230% undercount. The method identified significant heterogeneity and a broad non-Gaussian distribution of carbon nanotube uptake within cells. For example, while a particular cell contained an average of 1 nanotube per endosome, the heterogeneous distribution resulted in over 7 nanotubes localizing within some endosomes, substantially changing the accounting of subcellular nanoparticle concentration distributions. This work presents a method to quantify the cellular and subcellular concentrations of a heterogeneous carbon nanotube reference material, with implications for the nanotoxicology, drug/gene delivery, and nanosensor fields.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Nanopartículas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Nanopartículas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article