Your browser doesn't support javascript.
loading
Crosslinked zwitterionic polymeric ionic liquid-functionalized nitinol wires for fiber-in-tube solid-phase microextraction and UHPLC-MS/MS as an amyloid beta peptide binding protein assay in biological fluids.
Souza, Israel D; Anderson, Jared L; Queiroz, Maria Eugênia C.
Afiliação
  • Souza ID; Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil.
  • Anderson JL; Department of Chemistry, Iowa State University, Ames, IA, 50011, United States.
  • Queiroz MEC; Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil. Electronic address: mariaeqn@ffclrp.usp.br.
Anal Chim Acta ; 1193: 339394, 2022 Feb 08.
Article em En | MEDLINE | ID: mdl-35058015
ABSTRACT
Alzheimer disease (AD) is a neurodegenerative disorder characterized by extracellular accumulation of amyloidpeptide (Aß) in the brain interstitium. Human serum albumin (HSA) highly binds to Aß in blood plasma and is thought to inhibit plaque formation in peripheral tissue. Thus, the evaluation of albumin binding to Aß is an important key to understand the dynamics of these molecules in the biological system of patients with AD. In this work, a fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to estimate Aß fraction binding to HSA in cerebrospinal fluid (CSF) and plasma samples. Crosslinked zwitterionic polymeric ionic liquid (zwitterionic PIL)-coated nitinol wires were developed and packed into a polyether ether ketone (PEEK) capillary for a fiber-in-tube SPME and UHPLC-MS/MS method. Zwitterionic PIL sorbent was synthetized from 1-vinyl-3-(butanesulfonate)imidazolium ([VIm+C4SO3-]) and 1,12-di(3-vinylimidazolium)dodecane dibromide ([(VIm)2C12]2[Br]) monomers by in-situ thermally-initiated polymerization. Morphological characterization by scanning electron microscopy (SEM) and atomic force microscopy (AFM) revealed a decrease in the surface roughness of the nitinol wires from ∼17 nm to 1 nm after the in-situ polymerization. The zwitterionic PIL sorbent selectively preconcentrates Aß through a two-pronged interaction mechanism. The fiber-in-tube SPME and UHPLC-MS/MS method presented lower limits of quantification (LLOQ) of 0.4 ng mL-1 for Aß38 and 0.3 ng mL-1 for Aß40 and Aß42, a linear range from LLOQ values to 15 ng mL-1 with coefficients of determination higher than 0.99, precision with coefficient of variation (CV) values ranging from 2.1 to 7.3% and accuracy with relative standard deviation (RSD) values from -0.3 to 7.4. This method was successfully applied to evaluate the binding of HSA to Aß in cerebrospinal fluid (CSF) and plasma samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos beta-Amiloides / Líquidos Iônicos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos beta-Amiloides / Líquidos Iônicos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article