Your browser doesn't support javascript.
loading
Model-based dynamic off-resonance correction for improved accelerated fMRI in awake behaving nonhuman primates.
Shahdloo, Mo; Schüffelgen, Urs; Papp, Daniel; Miller, Karla L; Chiew, Mark.
Afiliação
  • Shahdloo M; Wellcome Centre for Integrative Neuroimaging, Department of Experimental Psychology, University of Oxford, Oxford, UK.
  • Schüffelgen U; Wellcome Centre for Integrative Neuroimaging, Department of Experimental Psychology, University of Oxford, Oxford, UK.
  • Papp D; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Miller KL; NeuroPoly Lab, Electrical Engineering Department, Polytechnique Montréal, Montreal, Canada.
  • Chiew M; Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
Magn Reson Med ; 87(6): 2922-2932, 2022 06.
Article em En | MEDLINE | ID: mdl-35081259
ABSTRACT

PURPOSE:

To estimate dynamic off-resonance due to vigorous body motion in accelerated fMRI of awake behaving nonhuman primates (NHPs) using the echo-planar imaging reference navigator, in order to attenuate the effects of time-varying off-resonance on the reconstruction.

METHODS:

In NHP fMRI, the animal's head is usually head-posted, and the dynamic off-resonance is mainly caused by motion in body parts that are distant from the brain and have low spatial frequency. Hence, off-resonance at each frame can be approximated as a spatially linear perturbation of the off-resonance at a reference frame, and is manifested as a relative linear shift in k-space. Using GRAPPA operators, we estimated these shifts by comparing the navigator at each time frame with that at the reference frame. Estimated shifts were then used to correct the data at each frame. The proposed method was evaluated in phantom scans, simulations, and in vivo data.

RESULTS:

The proposed method is shown to successfully estimate spatially low-order dynamic off-resonance perturbations, including induced linear off-resonance perturbations in phantoms, and is able to correct retrospectively corrupted data in simulations. Finally, it is shown to reduce ghosting artifacts and geometric distortions by up to 20% in simultaneous multislice in vivo acquisitions in awake-behaving NHPs.

CONCLUSION:

A method is proposed that does not need sequence modification or extra acquisitions and makes accelerated awake behaving NHP imaging more robust and reliable, reducing the gap between what is possible with NHP protocols and state-of-the-art human imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vigília / Imageamento por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vigília / Imageamento por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article