Your browser doesn't support javascript.
loading
Chemiluminescence sensors based on molecularly imprinted polymers for the determination of organophosphorus in milk.
Pan, Yinchuan; Liu, Xu; Liu, Jing; Wang, Jianping; Liu, Juxiang; Gao, Yanxia; Ma, Ning.
Afiliação
  • Pan Y; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China.
  • Liu X; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China.
  • Liu J; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China.
  • Wang J; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China.
  • Liu J; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China.
  • Gao Y; College of Animal Science, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China; Hebei Technology Innovation Center of Cattle and Sheep Embryo, Baoding, Hebei 071001, P.R. China; Hebei Research Institute of Dairy Industry Technology, Shijiazhuang, Hebei 050221, P.R. China. Electronic add
  • Ma N; College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei 071001, P.R. China. Electronic address: maning9618@163.com.
J Dairy Sci ; 105(4): 3019-3031, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35086700
ABSTRACT
As a food adapted to all kinds of people, milk has a high nutritional value. Because milk is a complex biological matrix, detecting illegal compounds is often difficult. As a common pesticide, organophosphorus (OP) residues caused by nonstandard use may be ignored, which is a threat to milk quality. In this study, using coumaphos as template molecule, the synthesized molecularly imprinted polymer (MIP) can specifically recognize 7 kinds of OP. Then, the MIP was used as an identification element to prepare a chemiluminescence sensor on a 96-well microplate for the determination of OP residues in milk samples. Due to the 4-(imidazol-1-yl)phenol-enhanced luminol-H2O2 system, the sensitivity of the system is very high; the detection limits of 7 OP including coumaphos, fenthion, chlorpyrifos, parathion, diazinon, fenchlorphos, and fenitrothion were 1 to 3 pg/mL, and the half maximal inhibitory concentrations were 1 to 20 ng/mL. The intraday recoveries of 7 OP were in the range of 86.1 to 86.5%, and the interday recoveries were in the range of 83.6 to 94.2%. Furthermore, the sensor can be reused up to 5 times. Therefore, the MIP-based chemiluminescence sensor can be used as a routine tool to detect OP residues in milk samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impressão Molecular Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impressão Molecular Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article