Post-treatment three-dimensional voxel-based dosimetry after Yttrium-90 resin microsphere radioembolization in HCC.
Veenstra, Emile B; Ruiter, Simeon J S; de Haas, Robbert J; Bokkers, Reinoud P H; de Jong, Koert P; Noordzij, Walter.
Afiliação
  • Veenstra EB; Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands. e.b.veenstra@umcg.nl.
  • Ruiter SJS; Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • de Haas RJ; Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Bokkers RPH; Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • de Jong KP; Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Noordzij W; Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
EJNMMI Res ; 12(1): 9, 2022 Feb 04.
Article em En | MEDLINE | ID: mdl-35122166
ABSTRACT

BACKGROUND:

Post-therapy [90Y] PET/CT-based dosimetry is currently recommended to validate treatment planning as [99mTc] MAA SPECT/CT is often a poor predictor of subsequent actual [90Y] absorbed dose. Treatment planning software became available allowing 3D voxel dosimetry offering tumour-absorbed dose distributions and dose-volume histograms (DVH). We aim to assess dose-response effects in post-therapy [90Y] PET/CT dosimetry in SIRT-treated HCC patients for predicting overall and progression-free survival (OS and PFS) and four-month follow-up tumour response (mRECIST). Tumour-absorbed dose and mean percentage of the tumour volume (V) receiving ≥ 100, 150, 200, or 250 Gy and mean minimum absorbed dose (D) delivered to 30%, 50%, 70%, and 90% of tumour volume were calculated from DVH's. Depending on the mean tumour -absorbed dose, treated lesions were assigned to a < 120 Gy or ≥ 120 Gy group.

RESULTS:

Thirty patients received 36 SIRT treatments, totalling 43 lesions. Median tumour-absorbed dose was significantly different between the ≥ 120 Gy (n = 28, 207 Gy, IQR 154-311 Gy) and < 120 Gy group (n = 15, 62 Gy, IQR 49-97 Gy, p <0 .01). Disease control (DC) was found more frequently in the ≥ 120 Gy group (79%) compared to < 120 Gy (53%). Mean tumour-absorbed dose optimal cut-off predicting DC was 131 Gy. Tumour control probability was 54% (95% CI 52-54%) for a mean tumour-absorbed dose of 120 Gy and 90% (95% CI 87-92%) for 284 Gy. Only D30 was significantly different between DC and progressive disease (p = 0.04). For the ≥ 120 Gy group, median OS and PFS were longer (median OS 33 months, [range 8-33 months] and median PFS 23 months [range 4-33 months]) than the < 120 Gy group (median OS 17 months, [range 5-33 months] and median PFS 13 months [range 1-33 months]) (p < 0.01 and p = 0.03, respectively).

CONCLUSIONS:

Higher 3D voxel-based tumour-absorbed dose in patients with HCC is associated with four-month DC and longer OS and PFS. DVHs in [90Y] SIRT could play a role in evaluative dosimetry.