Your browser doesn't support javascript.
loading
Reliability of IMU-Based Gait Assessment in Clinical Stroke Rehabilitation.
Felius, Richard A W; Geerars, Marieke; Bruijn, Sjoerd M; van Dieën, Jaap H; Wouda, Natasja C; Punt, Michiel.
Afiliação
  • Felius RAW; Research Group Lifestyle and Health, Utrecht University of Applied Sciences, 3584 CS Utrecht, The Netherlands.
  • Geerars M; Faculty of Human Movement Sciences, Vrije Universiteit Amsterdam, 1081 HV Amsterdam, The Netherlands.
  • Bruijn SM; Research Group Lifestyle and Health, Utrecht University of Applied Sciences, 3584 CS Utrecht, The Netherlands.
  • van Dieën JH; Physiotherapy Department Neurology, Rehabilitation Center de Parkgraaf, 3526 KJ Utrecht, The Netherlands.
  • Wouda NC; Faculty of Human Movement Sciences, Vrije Universiteit Amsterdam, 1081 HV Amsterdam, The Netherlands.
  • Punt M; Faculty of Human Movement Sciences, Vrije Universiteit Amsterdam, 1081 HV Amsterdam, The Netherlands.
Sensors (Basel) ; 22(3)2022 Jan 25.
Article em En | MEDLINE | ID: mdl-35161654
ABSTRACT

BACKGROUND:

Gait is often impaired in people after stroke, restricting personal independence and affecting quality of life. During stroke rehabilitation, walking capacity is conventionally assessed by measuring walking distance and speed. Gait features, such as asymmetry and variability, are not routinely determined, but may provide more specific insights into the patient's walking capacity. Inertial measurement units offer a feasible and promising tool to determine these gait features.

OBJECTIVE:

We examined the test-retest reliability of inertial measurement units-based gait features measured in a two-minute walking assessment in people after stroke and while in clinical rehabilitation.

METHOD:

Thirty-one people after stroke performed two assessments with a test-retest interval of 24 h. Each assessment consisted of a two-minute walking test on a 14-m walking path. Participants were equipped with three inertial measurement units, placed at both feet and at the low back. In total, 166 gait features were calculated for each assessment, consisting of spatio-temporal (56), frequency (26), complexity (63), and asymmetry (14) features. The reliability was determined using the intraclass correlation coefficient. Additionally, the minimal detectable change and the relative minimal detectable change were computed.

RESULTS:

Overall, 107 gait features had good-excellent reliability, consisting of 50 spatio-temporal, 8 frequency, 36 complexity, and 13 symmetry features. The relative minimal detectable change of these features ranged between 0.5 and 1.5 standard deviations.

CONCLUSION:

Gait can reliably be assessed in people after stroke in clinical stroke rehabilitation using three inertial measurement units.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acidente Vascular Cerebral / Reabilitação do Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acidente Vascular Cerebral / Reabilitação do Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article