Clinical and refractive outcomes after topography-guided refractive surgery planned using Phorcides surgery planning software.
Stulting, R Doyle; Lobanoff, Mark; Mann, Paul M; Wexler, Stephen; Stonecipher, Karl; Potvin, Richard.
Afiliação
  • Stulting RD; From the Woolfson Eye Institute, Atlanta, Georgia (Stulting); OVO LASIK + Lens, St. Louis Park, Minnesota (Lobanoff); Mann Eye Institute and Laser Centers, Houston, Texas (Mann); Washington University LASIK and Refractive Surgery Center, St. Louis, Missouri (Wexler); Laser Defined Vision, Greensboro, North Carolina (Stonecipher); Science in Vision, Bend, Oregon (Potvin).
J Cataract Refract Surg ; 48(9): 1010-1015, 2022 09 01.
Article em En | MEDLINE | ID: mdl-35171146
ABSTRACT

PURPOSE:

To evaluate prospectively the clinical outcomes of topography-guided laser in situ keratomileusis (LASIK) surgery performed with Contoura Vision using the Wavelight excimer laser and planned with the Phorcides Analytical Engine.

SETTING:

Four clinical practices in the U.S.

DESIGN:

Prospective single-arm interventional study.

METHODS:

130 eyes of 65 patients with myopia or myopic astigmatism were enrolled in a prospective study of visual and refractive outcomes after treatment with Contoura Vision using the Wavelight EX500 excimer laser to achieve optimal distance vision. At 3 months postoperatively, uncorrected distance visual acuity (UDVA), manifest refraction, and corrected distance visual acuity (CDVA) were measured and compared with previously published studies.

RESULTS:

At 3 months postoperatively, 100%, 89%, and 28% of eyes achieved UDVA of 20/20, 20/15, and 20/12.5 or better, respectively. 92% of eyes had postoperative UDVA equal to or better than their preoperative CDVA. Postoperative CDVA was equal to, 1 line better, or 2 lines better than the preoperative CDVA in 53%, 40%, and 6% of eyes, respectively. Only 1 eye lost 1 line of CDVA, and no eyes lost more than 1 line of CDVA. A statistically significant decrease was noted in subjective visual complaints, including glare, halos, difficulty driving at night, reading difficulty, starbursts, fluctuation in vision, and light sensitivity.

CONCLUSIONS:

The Phorcides Analytical Engine can be used to optimize visual outcomes for the correction of myopia and myopic astigmatism.