Sensitive detection of trace level Cd (II) triggered by chelation enhanced fluorescence (CHEF) "turn on": Nitrogen-doped graphene quantum dots (N-GQDs) as fluorometric paper-based sensor.
Naksen, Puttaraksa; Boonruang, Siwaluck; Yuenyong, Nunthawan; Lee, Hooi Ling; Ramachandran, Pravena; Anutrasakda, Wipark; Amatatongchai, Maliwan; Pencharee, Somkid; Jarujamrus, Purim.
Afiliação
  • Naksen P; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchatha
  • Boonruang S; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, 447 Sri-Ayuthaya Road, Phayathai, Ratchathewi, Bangkok, 10400, Thailand.
  • Yuenyong N; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchatha
  • Lee HL; Nanomaterials Research Group, School of Chemical Sciences, Universiti Sains Malaysia, 11800, USM, Penang, Malaysia.
  • Ramachandran P; Nanomaterials Research Group, School of Chemical Sciences, Universiti Sains Malaysia, 11800, USM, Penang, Malaysia.
  • Anutrasakda W; Green Chemistry for Fine Chemical Production and Environmental Remediation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Payathai Road, Patumwan, Bangkok, 10330, Thailand.
  • Amatatongchai M; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchatha
  • Pencharee S; Department of Physics, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
  • Jarujamrus P; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchatha
Talanta ; 242: 123305, 2022 May 15.
Article em En | MEDLINE | ID: mdl-35183979
ABSTRACT
Cadmium ion (Cd (II)) is a highly toxic heavy metal usually found in natural water. Exposure to Cd (II) can produce serious effects in human organs such as Itai-Itai disease. Therefore, the maximum allowance levels of Cd (II) in drinking water and herbal medicines imposed by the World Health Organization (WHO) are 3 µg L-1 and 300 µg kg-1, respectively. In this work, nitrogen-doped graphene quantum dots (N-GQDs) as a fluorescent sensor for Cd (II) determination was developed in both solution-based and paper-based systems. N-GQDs were synthesized from citric acid (CA) and ethylenediamine (EDA) via the hydrothermal method. The synthesized N-GQDs emitted intense blue fluorescence with a quantum yield (QY) of up to 80%. The functional groups on the surface of N-GQDs measured by FTIR were carboxyl (COO-), hydroxyl (OH-), and amine (NH2) groups, suggesting that they could be bound to Cd (II) for complexation. The fluorescence intensity of N-GQDs was gradually enhanced with the increase of Cd (II) concentration. This phenomenon was proved to result from the fluorescence enhancement (turn-on) based on the chelation enhanced fluorescence (CHEF) mechanism. Under the optimum conditions in the solution-based and paper-based systems, the limits of detection (LODs) were found to be 1.09 and 0.59 µg L-1, respectively. Furthermore, the developed sensors showed relatively high selectivity toward Cd (II) over ten other metal cations and six other anions of different charges. The performance of the sensor in real water and herbal medicine samples exhibited no significant difference as compared to the results of the validation method (ICP-OES). Therefore, the developed sensors can be used as fluorescent sensors for Cd (II) determination with high sensitivity, high selectivity, short incubation time (5 min). As such, the paper-based strategy has excellent promising potential for practical analysis of Cd (II) in water and herbal medicine samples with a trace level of Cd (II) concentrations.