Your browser doesn't support javascript.
loading
A CT-Based Radiomic Signature for the Differentiation of Pulmonary Hamartomas from Carcinoid Tumors.
Cangir, Ayten Kayi; Orhan, Kaan; Kahya, Yusuf; Ugurum Yücemen, Ayse; Aktürk, Islam; Ozakinci, Hilal; Gursoy Coruh, Aysegul; Dizbay Sak, Serpil.
Afiliação
  • Cangir AK; Department of Thoracic Surgery Ankara, Ankara University Faculty of Medicine (AUFM), Ankara 06100, Turkey.
  • Orhan K; Medical Design Application and Research Center (MEDITAM), Ankara University, Ankara 06100, Turkey.
  • Kahya Y; Medical Design Application and Research Center (MEDITAM), Ankara University, Ankara 06100, Turkey.
  • Ugurum Yücemen A; Department of Dental and Maxillofacial Radiodiagnostics, Medical University of Lublin, 20-093 Lublin, Poland.
  • Aktürk I; Department of Dentomaxillofacial Radiology, Ankara University Faculty of Dentistry, Ankara 06100, Turkey.
  • Ozakinci H; Department of Thoracic Surgery Ankara, Ankara University Faculty of Medicine (AUFM), Ankara 06100, Turkey.
  • Gursoy Coruh A; Department of Thoracic Surgery Ankara, Ankara University Faculty of Medicine (AUFM), Ankara 06100, Turkey.
  • Dizbay Sak S; Department of Thoracic Surgery Ankara, Ankara University Faculty of Medicine (AUFM), Ankara 06100, Turkey.
Diagnostics (Basel) ; 12(2)2022 Feb 05.
Article em En | MEDLINE | ID: mdl-35204507
ABSTRACT
Radiomics is a new image processing technology developed in recent years. In this study, CT radiomic features are evaluated to differentiate pulmonary hamartomas (PHs) from pulmonary carcinoid tumors (PCTs). A total of 138 patients (78 PCTs and 60 PHs) were evaluated. The Radcloud platform (Huiying Medical Technology Co., Ltd., Beijing, China) was used for managing the data, clinical data, and subsequent radiomics analysis. Two hand-crafted radiomics models are prepared in this study the first model includes the data regarding all of the patients to differentiate between the groups; the second model includes 78 PCTs and 38 PHs without signs of fat tissue. The separation of the training and validation datasets was performed randomly using an (82) ratio and 620 random seeds. The results revealed that the MLP method (RF) was best for PH (AUC = 0.999) and PCT (AUC = 0.999) for the first model (AUC = 0.836), and PC (AUC = 0.836) in the test set for the second model. Radiomics tumor features derived from CT images are useful to differentiate the carcinoid tumors from hamartomas with high accuracy. Radiomics features may be used to differentiate PHs from PCTs with high levels of accuracy, even without the presence of fat on the CT. Advances in knowledge CT-based radiomic holds great promise for a more accurate preoperative diagnosis of solitary pulmonary nodules (SPNs).
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article