Your browser doesn't support javascript.
loading
Comparison of Different Mass Spectrometry Workflows for the Proteomic Analysis of Tear Fluid.
Jones, Garrett; Lee, Tae Jin; Glass, Joshua; Rountree, Grace; Ulrich, Lane; Estes, Amy; Sezer, Mary; Zhi, Wenbo; Sharma, Shruti; Sharma, Ashok.
Afiliação
  • Jones G; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Lee TJ; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Glass J; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Rountree G; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Ulrich L; Department of Ophthalmology, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Estes A; Department of Ophthalmology, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Sezer M; Department of Ophthalmology, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Zhi W; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Sharma S; Center for Biotechnology and Genomic Medicine, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
  • Sharma A; Department of Ophthalmology, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA.
Int J Mol Sci ; 23(4)2022 Feb 19.
Article em En | MEDLINE | ID: mdl-35216421
ABSTRACT
The tear film is a multi-layer fluid that covers the corneal and conjunctival epithelia of the eye and provides lubrication, nutrients, and protection from the outside environment. Tear fluid contains a high concentration of proteins and has thus been recognized as a potential source of biomarkers for ocular disorders due to its proximity to disease sites on the ocular surface and the non-invasive nature of its collection. This is particularly true in the case of dry eye disease, which directly impacts the tear film and its components. Proteomic analysis of tear fluid is challenging mainly due to the wide dynamic range of proteins and the small sample volumes. However, recent advancements in mass spectrometry have revolutionized the field of proteomics enabling unprecedented depth, speed, and accuracy, even with small sample volumes. In this study using the Orbitrap Fusion Tribrid mass spectrometer, we compared four different mass spectrometry workflows for the proteomic analysis of tear fluid collected via Schirmer strips. We were able to establish a method of in-strip protein digestion that identified >3000 proteins in human tear samples from 11 healthy subjects. Our method offers a significant improvement in the number of proteins identified compared to previously reported methods without pooling samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Lágrimas / Proteômica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Lágrimas / Proteômica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article