"Shimming a Plate" Technique to Correct the Coronal Malalignment in Metadiaphyseal Distal Femur Fracture: Case Report.
Indian J Orthop
; 56(3): 501-504, 2022 Mar.
Article
em En
| MEDLINE
| ID: mdl-35251514
ABSTRACT
CASE We present a case of 19-year-old male patient with right sided comminuted metadiaphyseal distal femur fracture. Fixation was done using distal femur condylar locking plate. Washers were used with the screws to shimming the plate to achieve the coronal alignment and prevent stress over the screws. 2-year follow-up shows good alignment, radiological union and functional outcome without any complications. "Shimming" a locking plate with washers helps to achieve the better coronal alignment in comminuted metadiaphyseal distal femur fractures with coronal malalignment. It reduces the stress over screws and prevents implant-related complications.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2022
Tipo de documento: