Effectiveness of an actuator-driven pulsed water jet for removal of softened carious dentin.
Yokoyama-Sato, Yuka; Nishioka, Takashi; Naganuma, Yukihiro; Takahashi, Masatoshi; Nakagawa, Atsuhiro; Yoda, Nobuhiro; Sasaki, Keiichi; Takahashi, Nobuhiro; Tominaga, Teiji; Iikubo, Masahiro.
Afiliação
  • Yokoyama-Sato Y; Division of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry.
  • Nishioka T; Division of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry.
  • Naganuma Y; Clinics of Dentistry for Disabled, Tohoku University Hospital.
  • Takahashi M; Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry.
  • Nakagawa A; Department of Neurosurgery, Tohoku University Graduate School of Medicine.
  • Yoda N; Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry.
  • Sasaki K; Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry.
  • Takahashi N; Division of Oral Ecology and Biochemistry, Tohoku University Graduate School of Dentistry.
  • Tominaga T; Department of Neurosurgery, Tohoku University Graduate School of Medicine.
  • Iikubo M; Division of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry.
Dent Mater J ; 41(4): 527-533, 2022 Jul 30.
Article em En | MEDLINE | ID: mdl-35264543
ABSTRACT
The aim of this study was to assess the utility of an actuator-driven pulsed water jet (ADPJ) as a hardness-dependent carious dentin removal device by using different outputs. Thirty-six plane surface dental caries samples were treated with the ADPJ at 150, 200, and 250 voltage (12 teeth each). The Knoop hardness number (KHN) and Ca/P mass ratio were measured at 70 µm from the deepest point of the removing groove. Furthermore, three other teeth samples were manually treated with the ADPJ at the three above mentioned voltages (one tooth each) for 1 min. The KHN and Ca/P mass ratio were measured at 70 µm from the surface of the residual dentin part. In both the KHN and Ca/P mass ratio, higher residual dentin depended on the applied voltage of ADPJ. The ADPJ enabled the removal of softened carious dentin in an applied voltage-dependent manner.