Your browser doesn't support javascript.
loading
Deep Learning and Domain-Specific Knowledge to Segment the Liver from Synthetic Dual Energy CT Iodine Scans.
Mahmood, Usman; Bates, David D B; Erdi, Yusuf E; Mannelli, Lorenzo; Corrias, Giuseppe; Kanan, Christopher.
Afiliação
  • Mahmood U; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
  • Bates DDB; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
  • Erdi YE; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
  • Mannelli L; IRCCS SYNLAB SDN S.p.A., 80143 Naples, Italy.
  • Corrias G; Department of Radiology, University of Cagliari, 09124 Cagliari, Italy.
  • Kanan C; Chester F. Carlson Center for Imaging Science, Rochester Institute of Technology, Rochester, NY 14623, USA.
Diagnostics (Basel) ; 12(3)2022 Mar 10.
Article em En | MEDLINE | ID: mdl-35328225
ABSTRACT
We map single energy CT (SECT) scans to synthetic dual-energy CT (synth-DECT) material density iodine (MDI) scans using deep learning (DL) and demonstrate their value for liver segmentation. A 2D pix2pix (P2P) network was trained on 100 abdominal DECT scans to infer synth-DECT MDI scans from SECT scans. The source and target domain were paired with DECT monochromatic 70 keV and MDI scans. The trained P2P algorithm then transformed 140 public SECT scans to synth-DECT scans. We split 131 scans into 60% train, 20% tune, and 20% held-out test to train four existing liver segmentation frameworks. The remaining nine low-dose SECT scans tested system generalization. Segmentation accuracy was measured with the dice coefficient (DSC). The DSC per slice was computed to identify sources of error. With synth-DECT (and SECT) scans, an average DSC score of 0.93±0.06 (0.89±0.01) and 0.89±0.01 (0.81±0.02) was achieved on the held-out and generalization test sets. Synth-DECT-trained systems required less data to perform as well as SECT-trained systems. Low DSC scores were primarily observed around the scan margin or due to non-liver tissue or distortions within ground-truth annotations. In general, training with synth-DECT scans resulted in improved segmentation performance with less data.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article